.Part 4 SAN Extension and Bridging HP SAN Design Reference Guide 785354-001

Direct storage-to-storage
Fibre Channel switches
ESCON directors and repeaters
WDM
ATM and SONET/SDH
FCIP and routing extension
Direct storage-to-storage
Figure 124 (page 308) shows an HP P9000 (XP) Continuous Access direct storage-to-storage
configurations for Fibre Channel and ESCON. Table 159 (page 308) describes the maximum
supported distances.
Figure 124 HP P9000 (XP) Continuous Access direct storage-to-storage configurations for Fibre
Channel and ESCON
Local
Remote
25324a
RCU
I
RCU
I
Fibre
Channel
direct
connect
RCP
LCP
RCP
LCP
ESCON
direct
connect
Table 159 HP P9000 (XP) Continuous Access direct storage-to-storage distances
Maximum distanceConfiguration
150 m at 4 Gb/s
Fibre Channel (Fibre CHIP)
Port parameters for direct connect:
Fabric = Off, Connection = FC-AL
300 m at 2 Gb/s
500 m at 1 Gb/s
Long-wave SFPs: 10 km at 4 Gb/s
3 kmESCON
Fibre Channel switches
Figure 125 (page 309) shows an HP P9000 (XP) Continuous Access Fibre Channel configuration.
Table 160 (page 309) describes the maximum supported distances.
308 SAN extension