.Part 3 Host and Storage System Rules HP SAN Design Reference Guide 785353-001
• Bidirectional, asynchronous remote replication with automated initial normalization between
source and destination (up to 150 ms one-way latency for asynchronous mirroring)
NOTE: HP SVSP uses built-in iSCSI; therefore, no additional devices are required to connect
HP SVSP to the intersite IP network. For network requirements for asynchronous replication,
see Table 124 (page 246).
• Synchronous mirroring across 100 km or (0.5 ms) one way over a Fibre Channel network
• Native support for up to four site campus, metropolitan, and continental disaster-tolerant
configurations
• Front end virtual disk size of 1 GB to 16 TB
• Virtual disk groups to preserve write-order consistency across multiple virtual disks using the
Continuous Access feature
• HP SAN API server-based CLI that allows scripted access to VSM
• I/O continuation (no application disruption) during normalization and merging, and data
migration to another pool in the domain or storage array
• Multiple-path failover support
• Seamless, online, software and firmware upgrades
• Selective storage presentation for SAN-based data zoning
• Connectivity to Fibre Channel 2, 4, and 8 Gb/s switches
• Support for up to sixteen 4-port arrays, eight 8-port arrays, or some other combination up to
128 ports
For more information, see the HP StorageWorks SAN Virtualization Services Platform QuickSpecs
and other related SVSP documentation, available for download on the HP StorageWorks SAN
Virtualization Services Platform website http://www.hp.com/go/SVSP.
Software
HP SVSP software consists of the following:
• HP StorageWorks SAN Virtualization Services Platform Business Copy for copies within an
SVSP domain
• HP StorageWorks SAN Virtualization Services Platform Continuous Access for copies between
SVSP domains
• HP StorageWorks SAN Virtualization Services Platform thin provisioning
• HP StorageWorks SAN Virtualization Services Platform Volume Manager
• HP StorageWorks Virtualization Services Manager (VSM)
• HP StorageWorks Virtualization Services Manager Command Line Interface
NOTE: For the latest product support information, including operating system support, see the
product Quick Specs at http://www.hp.com/go/SVSP or SPOCK at: http://www.hp.com/storage/
spock. You must sign up for an HP Passport to enable access to SPOCK.
Hardware for a single SVSP domain
Hardware requirements are as follows:
• Minimum of one EVA, MSA, or XP
• High-availability dual-fabric environment (see “Level 4: multiple fabrics and device paths
(NSPOF)” (page 39))
SVSP storage systems 243