.Part 3 Host and Storage System Rules HP SAN Design Reference Guide 785353-001
= 0128 LUN presentationsLUNs #161 through #192 are presented to 4-node cluster
= 0008 LUN presentationsLUNs #193 through #200 are presented to single host
When all LUNs are presented to all hosts, the number of LUNs multiplied by the number of hosts
must not exceed 8,192.
Table 111 (page 225) lists the maximum number of EVA storage systems that can be configured
on a single server. There is no limit on the maximum number of EVA storage systems in a SAN.
Table 111 EVA single-server maximum configurations
LUNs per HBA target
3, 4
EVA storage systems per HBA
3
Operating systems
1, 2
Storage systems
2558
NAS EFS Clustered
Gateway - Linux Edition
SUSE SLES 9
EVA4100
EVA6100
EVA8100
648
NAS EFS Clustered
Gateway - Windows
Edition Windows
Storage Server 2003
25564Tru64 UNIX
5
EVA4100/4400
EVA6100
25516IBM AIX
EVA8100
25532HP-UX
EVA6400/8400
25516Linux (2.6 kernel)
P6300/P6500 EVA
P6350/P6550 EVA
12816Linux (2.4 kernel)
25532OpenVMS
25516Oracle Solaris
256 (per server)15VMware ESX 4.0, 3.x
6
128 (per server)15VMware ESX 2.5.x
6
255 (per server)16
Windows 2000
7
Windows 2003
Windows 2008
Windows 2012
8
25516Xen
1
For the supported operating system versions, see “Heterogeneous server rules” (page 165).
2
The maximum number of HBAs supported per server depends on the server model. (See the server documentation.) For Tru64 UNIX,
the maximum is 64 HBAs per server when using 5.1a (or earlier), 255 HBAs per server when using 5.1b (or later).
3
Multipath software may impose additional restrictions:
• Windows MPIO supports up to 32 paths per LUN.
• Secure Path for AIX supports up to 32 LUNs per HBA.
4
The maximum number of configurable LUNs per HBA target may be less based on performance requirements.
5
The P63xx/P65xx EVA is not supported with Tru64 UNIX.
6
VMware maximums are per VMware server, regardless of the number of guest operating systems. EVA6400/8400 is not supported
with ESX 2.5.x. The P63xx/P65xx EVA is not supported with ESX 2.5.x/3.x
7
Windows 2000 is not supported with the P63xx/P65xx EVA or EVA4400/6400/8400.
8
Windows 2012 is not supported with the EVA4100/6000/6100.
P6000/EVA storage 225