.Part 3 Host and Storage System Rules HP SAN Design Reference Guide 785353-001

Table 88 Tru64 UNIX SAN configuration rules
Tru64 UNIX SAN rules
Storage systems
1
All supported
Zoning is required when Tru64 UNIX is used in a heterogeneous SAN with other operating
systems.
Supports TruCluster Server.
Supports boot from SAN. For more information, see “P6000/EVA SAN boot support” (page 229)
and “P9000/XP SAN boot support” (page 238).
Supports multipathing high-availability configuration in multiple fabrics or in a single fabric with
zoned paths.
EVA4100
EVA6100
EVA8100
Zoning is required when a SAN is configured for multiple TruCluster products. Each TruCluster
must be in its own zone.
Supports connection of single HBA servers.
Supports active/active or active/passive failover mode.
A multipathing driver is embedded in the operating system.
For HP P6000 Continuous Access configuration information, see “HP P6000 Continuous Access
SAN integration” (page 228).
1
Unlisted but supported storage systems have no additional SAN configuration restrictions. For the latest support information, contact
an HP storage representative.
HP Tru64 UNIX SAN rules 195