.Part 2 Fabric Infrastructure Rules HP SAN Design Reference Guide 785352-001

Table 27 B-series Fibre Channel switch fabric rules (continued)
DescriptionRule number
B-series switches and routers supported routing modes with Continuous Access products:6
HP P9000 (XP) Continuous Access—Supported with port-based routing (aptpolicy = 1) or
exchange-based routing (aptpolicy = 3). See “HP P9000 (XP) Continuous Access FCIP gateway
support” (page 314).
HP P6000 Continuous Access—Supported with port-based routing (all XCS versions) or exchange-based
routing (XCS 09534000 or later). See “Network requirements for long-distance IP gateways with
XCS 11x, XCS 10x, or XCS 09x (page 297).
Routing policy—HP recommends that you use the same routing policy in all switches and routers within
a fabric.
EVA4400 Embedded Switch Module, 8 Gb Brocade—Supports connectivity to:7
Servers
Storage
Note: The EVA4400 Embedded Switch Module, 8 Gb Brocade supports the same connectivity to HP
storage systems as the 8/8, 8/24, and 8/80 switches.
Other B-series switches, including the EVA4400 Embedded Switch Module, 8 Gb Brocade
MPX200 Multifunction Router with iSCSI (see “MPX200 Multifunction Router with iSCSI for P6000/EVA
storage” (page 333)) and EVA and EVA4400 iSCSI Connectivity Option (see “EVA and EVA4400
iSCSI Connectivity Option (page 344))
MPX200 Multifunction Router with FCIP, HP IP Distance Gateway, and B-series 400 MP Router (see
“HP multi-protocol long-distance products (page 272))
Access Gateway (AG) requirements are:8
AG mode for Brocade 16Gb/16 SAN Switch for HP BladeSystem c-Class requires firmware 7.1.0_blv.
AG mode for HP SN3000B 16Gb FC Switch requires firmware 7.0.1 (or later).
AG mode for HP SN6000B 16Gb FC Switch requires firmware 7.0.0a (or later).
AG mode for Brocade 8Gb SAN Switch for HP BladeSystem c-Class and HP StorageWorks SAN
Switch 8/8 or 8/24 (with 24 ports enabled) requires firmware 6.1x (or later).
AG mode for the SAN Switch 8/40 requires firmware 6.2x (or later).
AG mode for the 2408 FCoE Converged Network Switch requires firmware 6.3.1a (or later).
AG mode for HP StorageWorks SAN Switch 4/8 or 4/16 requires firmware 5.3.0 (or later).
All switches that communicate with Access Gateway switches require firmware 5.1.x (or later). See
“BladeSystem with Brocade Access Gateway mode” (page 170).
In a fabric that contains a StorageWorks SAN Switch 4/8, 4/16, 4/32B, 4/64, SAN Director 2/128,
or SAN Director 4/256, Core switch addressing mode is required on all other switches in that fabric.
See “Core switch addressing mode” (page 120).
9
All B-series Fibre Channel switches and routers must use the HP default setting of dlsSet for
non-Continuous Access configurations and HP P6000 Continuous Access configurations running XCS
10
version 09534000 (or later) have two protocol options—HP Fibre Channel protocol or HP SCSI Fibre
Channel protocol. The settings for DLS and IOD functionality on the B-series switches should be configured
as follows:
HP Fibre Channel protocol:
dlsreset (DLS disabled)
iodset (IOD enabled)
HP SCSI Fibre Channel protocol:
dlsset (DLS enabled)
iodreset (IOD disabled)
Note: dlsset is the default policy when aptpolicy 3 (enable exchange-based routing) is enabled
on B-series switches.
For more information, see the HP P6000 Continuous Access Implementation Guide.
Fibre Channel switch fabric rules 105