HP StorageWorks Fabric Interoperability: Merging Fabrics Based on C-Series and M-Series Fibre Channel Switches Application Notes (AA-RVH9J-TE, May 2008)

Introduction
9Fabric Interoperability: Merging Fabrics Based on C-Series and M-Series Fibre Channel Switches Application Notes
Ensure the default Time Out Values are set properly
Verify R_A_TOV is set to 10 secs
Verify E_D_TOV is set to 2 secs
Launch EWS from your web browser
Enter the Username and Password and press OK
Select Configure/Switch/Fabric Parameters tab and verify R_A_TOV is 100 and
E_D_TOV is 20. Note that these values are in units of “tenths of a second”
If not, change them accordingly
Figure 7: Set Time Out values
Step M4: Disable Management Server
If the M-series product has a license key for Open Systems Management Server (OSMS),
ensure Management Server is disabled:
Launch EWS from your Web Browser
Enter the Username and Password and press OK
Select Configure/Management/OSMS
If it displays “OSMS Not Installed” no further action required
If not use HAFM and select Configure Management Server
From the “Configure Open Systems Management Server” dialog box, make sure the
Enable Management Server box and Host Control Prohibited box are not selected (not
checked)
Step M5: Verify proper Zoning Configuration is in place
For proper zoning merge and operation, ensure all zones are configured using only port
level device WNNs