HP StorageWorks Fabric Interoperability: Merging Fabrics Based on C-Series and M-Series Fibre Channel Switches Application Notes (AA-RVH9J-TE, May 2008)

Introduction
6 Fabric Interoperability: Merging Fabrics Based on C-Series and M-Series Fibre Channel Switches Application Notes
Verify Active Domain ID
To Change the Domain ID, select the Configure Tab, the Switch Tab and then Parameters
Tab
In the Preferred Domain ID field, enter the Domain ID you want to use. In this example
the Domain ID is 4
Note: Select the domain IDs in the range 1-31 and this actually translates to 97-127 domain IDs in
the Interop Mode (all numbers are in decimal).
Figure 2: Launch EWS and verify and configure switch domain ID
Figure 3: Configure domain ID
Step M3: Verify switch/fabric default settings
Ensure Interop mode is set to Open Fabric: