Introduction
16 Fabric Interoperability: Merging Fabrics Based on C-Series and M-Series Fibre Channel Switches Application Notes
Contiguous-allocation: Disabled
Configured fabric name: 41:6e:64:69:61:6d:6f:21
Configured priority: 128
Configured domain ID: 0x64(100) (preferred)
Principal switch run time information:
Running priority: 2
Interface Role RCF-reject
---------------- ------------- ------------
fc2/1 Downstream Disabled
fc2/2 Downstream Disabled
fc2/7 Upstream Disable
MDS9509# show fcdomain domain-list vsan 1
Number of domains: 2
Domain ID WWN
--------- -----------------------
0x61(97) 10:00:08:00:88:a0:b0:ae [Principal]
0x78(120) 20:08:00:05:30:00:1c:5f [Local]
Perform the following the command on the ports configured as E-ports
Example:
MDS9509# show interface fc2/4
fc2/4 is up
Hardware is Fibre Channel, FCOT is short wave laser
Port WWN is 20:44:00:05:30:00:1c:5e
Peer port WWN is 20:10:08:00:88:a0:b0:ae
Admin port mode is auto, trunk mode is on
Port mode is E, FCID is 0x780000
Å
verify mode is E-Port
Port vsan is 8
Speed is 1 Gbps
Transmit B2B Credit is 16
Receive B2B Credit is 16
Receive data field Size is 2112
Beacon is turned off
5 minutes input rate 40 bits/sec, 5 bytes/sec, 0 frames/sec
5 minutes output rate 32 bits/sec, 4 bytes/sec, 0 frames/sec