HP StorageWorks Fabric Interoperability: Merging Fabrics Based on C-Series and M-Series Fibre Channel Switches Application Notes (AA-RVH9J-TE, May 2008)
Introduction
11Fabric Interoperability: Merging Fabrics Based on C-Series and M-Series Fibre Channel Switches Application Notes
Step C1: Verify Switch Firmware Versions
Verify all C-series switches are configured with the proper firmware version as shown in
Table 4. If necessary upgrade the switches with the correct firmware and refer to MDS 9000
Family Configuration Guide that can be accessed through the links provided at the following
URL.
http://h18006.www1.hp.com/products/storageworks/cmds9506/leavinghp-cisco.html
sanergy4(MDS9506)# show ver
Cisco Storage Area Networking Operating System (SAN-OS) Software
TAC support: http://www.cisco.com/tac
Copyright (c) 2002-2003 by Cisco Systems, Inc. All rights reserved.
The copyright for certain works contained herein are owned by
Andiamo Systems, Inc. and/or other third parties and are used and
distributed under license.
Software
BIOS: version 1.0.8
loader: version 1.1(2)
kickstart: version 1.2(1a)
system: version 1.2(1a)
BIOS compile time: 08/07/03
kickstart image file is:
bootflash:/m9500-sf1ek9-kickstart-mz.1.2.1a.
kickstart compile time: 8/24/2003 13:00:00
system image file is: bootflash:/m9500-sf1ek9-mz.1.2.1a.bin
system compile time: 8/24/2003 13:00:00
Step C2: Verify switch/fabric default settings
It may be necessary to change the Fibre Channel timers as well if they have been changed
from the system defaults. The MDS 9000 and B-series FC Error Detect (ED_TOV) and
Resource Allocation (RA_TOV) timers default to the same values. They can be changed if
needed. The RA_TOV default is 10 seconds, and the ED_TOV default is 2 seconds. Per the
FC-SW2 standard, these values must be the same on each switch within the fabric.
MDS9509 login: admin
Password: xxxxxxxx
MDS9509# show fctimer
F_S_TOV : 5000 milliseconds
D_S_TOV : 5000 milliseconds
E_D_TOV : 2000 milliseconds
R_A_TOV : 10000 milliseconds
To modify these values, use the following commands. Note that these changes can not be
made unless all VSANs in the switch are suspended.