HP StorageWorks Fabric interoperability: Merging fabrics based on C-series and B-series Fibre Channel switches application notes Abstract This document is intended for customers who are merging one SAN fabric constructed with C-series SAN switches and another fabric constructed with B-series SAN switches.
Legal and notice information © Copyright 2004-2009 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein. Microsoft® and Windows® are U.S.
Introduction This document discusses the details on merging fabrics based on C-series and B-series Fibre Channel switches into a single, standards-based, interoperable fabric. This document also provides information on: • Supported configurations • Expected behavior • Exceptions in the interoperability mode.
C-series merge preparation Step 1: Verify switch firmware versions, page 6 Step 2: Verify switch/fabric default settings, page 7 Step 3: Verify the fabric operating mode, page 7 Step 4: Verify and configure switch domain IDs, page 8 Step 5: Verify zoning configuration, page 8 B-series configuration steps The following steps provide information about verifying and configuring B-series switches for interoperability with a C-series SAN fabric.
Configure... Fabric parameters (yes, y, no, n): [no] y Domain: (1..239) [97] [Select the domain ID in the range 97-127, if change is required] BB credit: (1..27) [16] R_A_TOV: (4000..120000) [10000][Ensure this value is 10000 for all switches in the fabric] E_D_TOV: (1000..5000) [2000][Ensure this value is 2000 for all switches in the fabric] WAN_TOV: (1000..120000) [0] Data field size: (256..2112) [2112] Sequence Level Switching: (0..1) [0] Disable Device Probing: (0..1) [0] Suppress Class F Traffic: (0..
Switch:admin> interopmode 1 The switch effective configuration will be lost when the operating mode is changed; do you want to continue? (yes, y, no, n): [no] y Committing configuration...done.
Use the sho ver command to verify the firmware version: MDS9509# show ver Cisco Storage Area Networking Operating System (SAN-OS) Software TAC support: http://www.cisco.com/tac Copyright (c) 1986-2002 by cisco Systems, Inc. Software kickstart: version 1.0(1) [build 1.0(0.260c)] [gdb] system: version 1.0(1) [build 1.0(0.
Step 4: Verify and configure switch domain IDs Assign a domain ID in the range of 97–127 (0x61–0x7F). There is a maximum of 31 switches allowed in the fabric while in interoperability mode. In the MDS the default is to request an ID from the principal switch. If the preferred keyword is used, the MDS requests a specific ID, but still join the fabric if the principal switch assigns a different ID.
• Any character other than the first character must be either an upper case (A–Z) or lower case (a–z) letter, a number (0–9) or an underscore symbol (_). Configure zones using port WWNs In interoperability mode, all zone members must be defined using port WWNs. Defining them any other way is not supported. Zones cannot be defined using Fibre Channel port addresses or domain and port combinations. If there are any zones not defined with the port WWN, you must redefine them.
interoperability mode:yes [verify mode] loadbalancing:src-id/dst-id/oxid operational state:up MDS9509# show fcdomain vsan 1 The local switch is a Subordinated Switch.
Interoperability mode behavior summary by switch type This section provides information about interoperability mode behavior the switches. C-series The MDS series of switches are limited in the following areas when interoperating with non-MDS switches: • Interop mode only affects the specified VSAN. The MDS-9000 can operate with full functionality in other non-interop mode VSANS.
B-series The following is a summary of interoperability mode behavior on B-series switches. • The Msplmgmtdeactivate command must be run prior to connecting it to any C-series, or else the fabric will be segmented. • Zoning can only be defined with port WWNs. Port numbers and NWWNs are not valid fields to zone by. • To manage zoning administration from a B-series switch, all B-series must be interconnected to facilitate the forwarding of the inactive zone configuration also.
MDS9509(config-zone)# member pwwn 21:00:00:20:37:28:31:6d MDS9509(config-zone)# member pwwn 21:00:00:20:37:28:24:7b MDS9509(config-zone)# member pwwn 21:00:00:20:37:28:22:ea MDS9509(config-zone)# member pwwn 21:00:00:20:37:28:2e:65 MDS9509(config-zone)# member pwwn 21:00:00:20:37:28:26:0d MDS9509(config-zone)# MDS9509(config-zone)# exit MDS9509(config)# MDS9509(config)# MDS9509(config)# zoneset name mdscore vsan 1 MDS9509(config-zoneset)# member vz1 MDS9509(config-zoneset)# member vz2 MDS9509(config-zoneset
Switch3800:admin> cfgshow Defined configuration: cfg: bzones bz1, bz2 zone: bz1 10:00:00:00:c9:24:3d:90; 50:06:01:60:88:02:90:cb zone: bz2 10:00:00:00:c9:24:3f:75; 21:00:00:20:37:a7:ca:b7; 21:00:00:20:37:a7:c7:e0; 21:00:00:20:37:a7:c7:df Effective configuration: cfg: mdscore zone: vz1 50:06:01:60:88:02:90:cb 10:00:00:00:c9:24:3d:90 zone: vz2 10:00:00:00:c9:24:3f:75 21:00:00:20:37:a7:ca:b7 21:00:00:20:37:a7:c7:e0 21:00:00:20:37:a7:c7:df zone: vz3 10:00:00:e0:69:f0:43:9f 21:00:00:20:37:28:31:6d 21:00:00:20:37
Switch3800:admin> zoneAdd "vz33", "21:00:00:20:37:28:2e:65; 21:00:00:20:37:28:26:0d" Verify the zones before making them active: Switch3800:admin> zoneShow Defined configuration: zone: vz11 10:00:00:00:c9:24:3d:90; 50:06:01:60:88:02:90:cb zone: vz22 10:00:00:00:c9:24:3f:75; 21:00:00:20:37:a7:ca:b7; 21:00:00:20:37:a7:c7:e0; 21:00:00:20:37:a7:c7:df zone: vz33 10:00:00:e0:69:f0:43:9f; 21:00:00:20:37:28:31:6d; 21:00:00:20:37:28:24:7b; 21:00:00:20:37:28:22:ea; 21:00:00:20:37:28:2e:65; 21:00:00:20:37:28:26:0d Ef
MDS9509# show zoneset active zoneset name mdscore1 vsan 1 zone name vz11 vsan 1 * fcid 0x610400 [pwwn 10:00:00:00:c9:24:3d:90] * fcid 0x630500 [pwwn 50:06:01:60:88:02:90:cb] zone name vz22 vsan 1 * fcid 0x630400 [pwwn 10:00:00:00:c9:24:3f:75] * fcid 0x6514e2 [pwwn 21:00:00:20:37:a7:ca:b7] * fcid 0x6514e4 [pwwn 21:00:00:20:37:a7:c7:e0] * fcid 0x6514e8 [pwwn 21:00:00:20:37:a7:c7:df] zone name vz33 vsan 1 * fcid 0x651500 [pwwn 10:00:00:e0:69:f0:43:9f] * fcid 0x6105dc [pwwn 21:00:00:20:37:28:31:6d] * fcid 0x610
NOTE: Cisco NPV mode can be supported with Brocade fabric configured in interopmode or Native mode. If the MDS9124e NPV is connected to an external fabric comprising of only Brocade switches, use Brocade Native mode only. If the MDS 9124e NPV is connected to an external fabric with a mix of Brocade and Cisco switches, then Brocade (and Cisco) switches must be set to interopmode 1. • Brocade AG mode is supported with FOS-OS 5.2.1b or later.
Table 2 Supported B-series product line switches HP StorageWorks switch name HP StorageWorks SAN Switch 2/8 EL, 2/8 power pack HP StorageWorks SAN Switch 2/16, 2/16 EL, 2/16 power pack Firmware version 3.2.1a 3.2.1b Number of ports 8 16 5.0.1d 5.1.0b HP StorageWorks SAN Switch 2/8V TAA, 2/8V TAA power pack, 2/16V, 2/16V TAA, 2/16N FF, 2/16N TAA power pack, 2/32, 2/32 power pack 5.1.0d HP StorageWorks SAN Director 2/128 5.3.0b 5.2.1b 5.3.0 8, 16, 32, 128 5.3.1a 5.3.1b 5.0.1d 5.1.
HP switch name Compaq StorageWorks switch name Firmware version Number of ports HP Brocade 2400 (HP reseller) Compaq StorageWorks SAN Switch 8 8 N/A Compaq StorageWorks SAN Switch 8-EL 8 HP Brocade 2800 (HP reseller) Compaq StorageWorks SAN Switch 16 16 N/A Compaq StorageWorks SAN Switch 16-EL 2.6.1c 16 2.6.
Table 3 Supported C-series product line switches Switch name Firmware version Number of ports MDS 9513 Up to 528 MDS 9506 Up to 128 MDS 9509 Up to 224 MDS 9216 MDS 9216A 2.1(2d) 3.0(2a) 3.0(3) 3.1(2a) MDS 9216i 3.1(3) 3.1.(3a) MDS 9120 MDS 9140 MDS 9124 MDS 9124e 3.2(1a) 3.2(2c) 3.2(3) 3.3(1a) 3.
Table 4 Supported operating system versions Multipath software nl OS OS version HBA Windows 2000 AS SP3 Secure Path 4.0c QLA 2342, LP8000 Windows 2003 AS SP2 Secure Path 4.0c LP952 Driver/firmware/BIOS (minimum required) 8.2.0.71 / 1.33 5-4.82a16 / 3.91a1 / 1.63a1 5-4.82a16 / 3.91a1 / 1.63a1 11.00.10 PHSS_26798 HP-UX 11.00/11.11 Auto Path 2.01.02 11.11.09 PHKL_26799 A6795A PDC 42.19 OpenVMS 7.3-1 Native DS-KGPSA-CA Native/ 3.91a1 Tru64 UNIX 5.1B Native DS-KGPSA-CA Native/ 3.
Table 6 HP p-Class BladeSystem support HP p-Class BladeSystem Fibre Channel interface nl Operating system Embedded switch Storage systems Microsoft Windows 2003 Windows 2000 BL20p Red Hat Enterprise Linux 3 and 4 (X86) QLogic ISP2312 based dual port Fibre Channel card SLES 8 (X86) SLES 9 (X86) BL60p HP-UX 11i Brocade 4 Gb SAN switch for HP pClass BladeSystem XP EVA QLogic ISP2312 Fibre Channel ports (2 Gb/s) Table 7 HP c-Class BladeSystem support HP c-Class BladeSystem Fibre Channel interface
• HP StorageWorks Fabric interoperability: Merging fabrics based on M-series and B-series Fibre Channel switches • HP StorageWorks Fabric interoperability: Merging fabrics based on M-series and C-series Fibre Channel switches Additional documentation, including white papers and best practices documents, are available on the HP website: http://www.hp.com.