HP StorageWorks B-Series Remote Replication Solution Best Practices Guide (5697-6731, June 2007)

NOTE:
Although not covered here, the procedures for the MP Router blades a re identical, but some
screen shots will differ slightly given the blade orientation in the director chassis. To start
this procedure on a blade router, p oint your browser to the IP address of the Director.
Conguring Fibre Channel routing (FCR)
To congure the Fibre Channel routing using Web Tools:
1. Launch the FC routing module via the FCR button in the Switch View on the router.
A tabbed interface displays, from which you can access the functions required to enable FCR
on the switch you are connected to.
2. Ensure that the backbone fabric ID of the switch is the same as other FCRs in the backbone fabric.
Click Set Fabric ID and either enter the FI D value or select it from the drop-down m enu.
3. Enable Fibre Channel routing (FCR) .
a. Click Enable FCR.
b. Click Yes to conrm.
4. Ensure that the ports to congure as EX-Ports are not connected or are disabled.
5. Congure the EX-Por ts:
a. Click the EX-Ports tab.
b. Select New to launch the EX-Port Conguration wizard.
c. Selecttheporttobecongured. For this example, select port 0 and click Next to continue.
d. Set the Port Pa rameters (FID) and Interop mode; set the FC op erational parameters.
e. Conrm the settings.
6. Connect the EX-Ports to the proper edge fabric if they are not already connected:
a. Connect the cables. Do not enable the por ts yet.
b. Close the FCR Admin window.
7. Congure LSAN zones on the fabrics that share devices using the Zone Administra tion module of
Web Tools:
a. Use the browser to launch the Switch View on the e dge fabric switch.
b. Click zone admin tolaunchtheZoneAdministrationmodule.
32
Solution setup