Fabric OS Message Reference v7.0.0 (53-1002149-01, April 2011)
518 Fabric OS Message Reference
53-1002149-01
PLAT-1003
81
Severity CRITICAL
PLAT-1003
Message <timestamp>, [PLAT-1003], <sequence-number>, FFDC, CRITICAL, <system-name>, <Info
message> Slot <Blade Slot number> C/BE: <Captured Command/Byte-Enables data>
ADBUS: <Captured AD bus data> misc_intr <Bridge reset interrupts>.
Probable Cause Indicates a PCI bus hang was detected.
Recommended
Action
The FRU must be replaced.
Severity CRITICAL
PLAT-1004
Message <timestamp>, [PLAT-1004], <sequence-number>, FFDC, CRITICAL, <system-name>,
Switch has older FPGA rev 0x<FPGA version already installed in HW>; please upgrade
to newer rev 0x<FPGA version which Fabric OS carries> via the fpga_update command.
Probable Cause Indicates Fabric OS has a newer FPGA version.
Recommended
Action
Upgrade FPGA to new version.
Severity CRITICAL