Fabric OS Message Reference v7.0.0 (53-1002149-01, April 2011)

Fabric OS Message Reference 419
53-1002149-01
HIL-1613
48
HIL-1613
Message <timestamp>, [HIL-1613], <sequence-number>,, INFO, <system-name>, PSU-FAN FRUS
Air Flow matched. System shutdown canceled.
Probable Cause Indicates that PSU FAN Air Flows have changed to same direction. System can continue operation.
Applicable only to Brocade 6510.
Recommended
Action
Ensure that the fan units have same direction.
Severity INFO
HIL-1650
Message <timestamp>, [HIL-1650], <sequence-number>, ERROR, <system-name>, <failure count>
unable to detect both WWN cards in chassis. Access to WWN halted.
Probable Cause One or both of the WWN cards is missing. Both WWN cards must be present for normal operation.
Recommended
Action
Make sure both WWN cards are inserted.
Severity ERROR