Fabric OS Message Reference v7.0.0 (53-1002149-01, April 2011)

418 Fabric OS Message Reference
53-1002149-01
HIL-1610
48
Recommended
Action
No action required.
Severity INFO
HIL-1610
Message <timestamp>, [HIL-1610], <sequence-number>,, WARNING, <system-name>, Fan/PS unit
<Combo fan/power supply unit number> not supplying power, fan speeds may not be
available. Please ensure that the unit has power and the switch is on.
Probable Cause Indicates that the power supply is not connected to a power source or it is not switched on or the
unit is faulty. Applicable only to Brocade 5100 and Brocade 6510.
Recommended
Action
Ensure that the power cord is connected to the unit with a valid power source and then switch on
the unit. If the problem persists, try reseating the unit. If the problem still persists replace the FRU.
Severity WARNING
HIL-1611
Message <timestamp>, [HIL-1611], <sequence-number>, FFDC, CRITICAL, <system-name>,
MISMATCH in PSU-FAN Air Flow direction. Replace PSU with fan air flows in same
direction. System will be shut down in 2 minutes.
Probable Cause Indicates that PSU FAN Air Flows are in reverse direction. Could heat up the system. Replace PSU
with airflow in same direction otherwise the system will shutdown. Applicable only to Brocade
6510.
Recommended
Action
Ensure fan units have same direction. Check fan directions with chassisshow command.
Severity CRITICAL
HIL-1612
Message <timestamp>, [HIL-1612], <sequence-number>,, CRITICAL, <system-name>, MISMATCH in
PSU-FAN Air Flow direction.System shut down.
Probable Cause Indicates that PSU FAN Air Flows are in reverse direction. System will be shut down. Applicable only
to Brocade 6510.
Recommended
Action
Ensure fan units have same direction.
Severity CRITICAL