Fabric OS Message Reference v7.0.0 (53-1002149-01, April 2011)
Fabric OS Message Reference 343
53-1002149-01
FW-1172
45
Probable Cause Indicates that the number of signal losses that the port experiences has changed from a value
outside of the acceptable range to a value within the acceptable range. Loss of signal generally
indicates a physical problem.
Recommended
Action
No action is required. Respond to this message as is appropriate to the particular policy of the
end-user installation. Frequent loss of signal generally indicates a physical problem.
Check both ends of your cable connection. Verify that the cable and small form-factor pluggables
(SFPs) are not faulty.
Severity INFO
FW-1172
Message <timestamp>, [FW-1172], <sequence-number>,, INFO, <system-name>, <Port Name>,
<Label>, value has changed(High=<High value>, Low=<Low value>). Current value is
<Value> <Unit>.
Probable Cause Indicates that the number of protocol errors that the port experiences has changed. Occasional
protocol errors occur due to software glitches. Persistent protocol errors occur due to hardware
problems.
Recommended
Action
Check both ends of your cable connection. Verify that the cable and small form-factor pluggable
(SFP) are not faulty.
Severity INFO
FW-1173
Message <timestamp>, [FW-1173], <sequence-number>,, INFO, <system-name>, <Port Name>,
<Label>, is below low boundary(High=<High value>, Low=<Low value>). Current value
is <Value> <Unit>.
Probable Cause Indicates that the number of protocol errors that the port experiences has fallen below the low
boundary. Occasional protocol errors occur due to software glitches. Persistent protocol errors
occur due to hardware problems. A low number of protocol errors means that the switch is
functioning normally.
Recommended
Action
No action is required. Respond to this message as is appropriate to the particular policy of the
end-user installation.
Severity INFO
FW-1174
Message <timestamp>, [FW-1174], <sequence-number>,, WARNING, <system-name>, <Port Name>,
<Label>, is above high boundary(High=<High value>, Low=<Low value>). Current value
is <Value> <Unit>.