Fabric OS Message Reference v7.0.0 (53-1002149-01, April 2011)

212 Fabric OS Message Reference
53-1002149-01
FABR-1049
29
FABR-1049
Message <timestamp>, [FABR-1049], <sequence-number>,, ERROR, <system-name>, Detected
Fabric ID (FID <InheritedFID> inherited) conflict with neighbor switch
<Switchname> (domain <Domain ID>, FID <Fabric ID>). E-ports (<Number of E-ports
disabled>) connected to the switch are disabled.
Probable Cause Indicates that the neighbor switch has Fabric ID conflict with the inherited FID of the local switch.
All E_ports directly connected to the conflicting switch are disabled.
Recommended
Action
Make sure that all the switches in the fabric have same Fabric ID or upgrade the switch firmware to
a VF-capable firmware.
Severity ERROR
FABR-1050
Message <timestamp>, [FABR-1050], <sequence-number>,, INFO, <system-name>, <License>
license not present. F-port trunking cannnot be enabled on port(<Port>).
Probable Cause Indicates that the Trunking or SAO license is not installed.
Recommended
Action
Install the required license.
Severity INFO
FABR-1051
Message <timestamp>, [FABR-1051], <sequence-number>,, ERROR, <system-name>, D-Port
<Testname> loopback test failed for slot <Slot> and port <Port>.
Probable Cause Indicates that the D-Port test failed for the given slot and port due to one of the following reasons:
The SFP fault detected by Electrical loopback test failure.
The cable fault detected by optical loopback test failure.
An ASIC issue detected by remote loopback test failure.
Recommended
Action
Replace the faulty SFPs, cables, or blade.
Severity ERROR
FABR-1052
Message <timestamp>, [FABR-1052], <sequence-number>,, INFO, <system-name>, The configured
port speed (16G/10G on non C3 blade or 1G on C3 blade) is invalid. Persistently
disabling port <Port that is being disabled>.