Fabric OS Message Reference v7.0.0 (53-1002149-01, April 2011)
Fabric OS Message Reference 149
53-1002149-01
CVLC-1029
21
Probable Cause Indicates a warning event.
Recommended
Action
Perform a manual rekey on this LUN.
Severity WARNING
CVLC-1029
Message <timestamp>, [CVLC-1029], <sequence-number>,, WARNING, <system-name>, Mirror LUN
is disabled as primary LUN is being rekeyed without splitting the mirror.
Container: <Target container name>, Initiator: <Initiator physical WWN>, LUN ID:
<LUN ID>.
Probable Cause Indicates performing FTE or manual rekey of primary LUN without splitting the mirror.
Recommended
Action
Break the mirror and re-establish the mirror after rekey on primary LUN is complete.
Severity WARNING
CVLC-1030
Message <timestamp>, [CVLC-1030], <sequence-number>,, WARNING, <system-name>, Primary LUN
may be out of sync with mirror LUN.
Container: <Target container name>, Initiator: <Initiator physical WWN>, LUN ID:
<LUN ID>.
Probable Cause Indicates the manual rekey was completed on primary LUN.
Recommended
Action
1. Make the target ports of the mirror LUN offline to hosts.
2. Re-establish the mirror.
3. Once the mirror is in sync, split the mirror.
4. Bring back the target ports of the mirror LUN online.
Severity WARNING
CVLC-1031
Message <timestamp>, [CVLC-1031], <sequence-number>,, WARNING, <system-name>, Primary LUN
is restored from mirror LUN. LUN in read-only mode.
Container: <Target container name>, Initiator: <Initiator physical WWN>, LUN ID:
<LUN ID>.
Probable Cause Indicates a rekeyed primary LUN may have been restored from mirror LUN without synchronizing.
Recommended
Action
1. Create a new primary LUN.
2. Add it to its container with -newLUN option.