Fabric OS Message Reference v7.0.0 (53-1002149-01, April 2011)
38 Fabric OS Message Reference
53-1002149-01
AN-1004
3
AN-1004
Message <timestamp>, [AN-1004], <sequence-number>,, WARNING, FABRIC, <system-name>,
Congestion bottleneck on port <slot number>/<port number within slot number>.
<percentage of seconds affected by congestion bottlenecking> pct. of <observation
period over which the percentage of affected seconds is reported> secs. affected.
Probable Cause Indicates that the volume of outgoing traffic at this port is too high for the capacity of the link.
Recommended
Action
Add more capacity on the path, using trunk links if possible.
Severity WARNING
AN-1005
Message <timestamp>, [AN-1005], <sequence-number>,, INFO, FABRIC, <system-name>, Slot
<slot number>, port <port number within slot number> has <bottleneck type>
bottleneck cleared.
Probable Cause Indicates that the bottleneck was cleared on the port.
Recommended
Action
No action is required.
Severity INFO
AN-1010
Message <timestamp>, [AN-1010], <sequence-number>,, WARNING, FABRIC, <system-name>,
Severe latency bottleneck detected at Slot <slot number> port <port number within
slot number>.
Probable Cause Indicates a credit loss.
Recommended
Action
Contact your vendor's customer support for assistance.
Severity WARNING
AN-1011
Message <timestamp>, [AN-1011], <sequence-number>,, WARNING, FABRIC, <system-name>, Could
not distinguish between primary and dependent severe latency bottleneck on slot
<slot number> port <port number within slot number> because port mirroring is
enabled on this port.
Probable Cause Indicates that the port mirroring uses the required resources to distinguish between primary and
dependent severe latency bottleneck.