Brocade Network Advisor SAN User Manual v12.0.0 (53-1002696-01, April 2013)

Brocade Network Advisor SAN User Manual 741
53-1002696-01
LSAN zones
21
6. Select an option from the Type list.
By default, the first time you launch the LSAN Zoning dialog box for a zoning scope, the
Potential Members list displays valid members using the following rules:
If you select the WWN type, the valid members display by the Attached Ports.
If you select the WWN-Fabric Assigned type, the valid members display by the ports on
which FA-PWWN is configured.
For DCB-capable switches, you may need to change the port display options to see the ports.
Right-click in the Potential Members list and select Port Display to change the options.
7. Click the right arrow between the Potential Members list and the Zones list to add the selected
members to the zone.
8. Click Activate.
9. Review the information in the Activate LSAN Zones dialog box.
10. Click OK to activate the LSAN zones.
A message displays informing you that the zones you change will be saved in the zone
database and asking whether you want to proceed. Click Yes to confirm the activation, or click
No to cancel the activation.
11. Click OK to continue.
All LSAN zones are activated on the selected fabrics and saved to the zone database.
12. Click OK to close the Zoning dialog box.
Creating a new member in an LSAN zone
Use this procedure to add a member to an LSAN zone when the member is not listed in the
Potential Members list of the Zone DB tab.
For instructions to add a member to a zone when the member is listed in the Potential Members
list, refer to the procedure Adding members to the LSAN zone” on page 740.
1. Select a backbone fabric from the Connectivity Map or Product List.
2. Select Configure > Zoning > LSAN Zoning (Device Sharing).
The Zone DB tab of the Zoning dialog box displays.
3. Select one or more zones to which you want to add members in the Zones list. (Press SHIFT or
CTRL and click each zone name to select more than one zone.)
4. Click New Member.
The Add Zone Member dialog box displays.
5. Add the new member by port WWN by completing the following steps.
a. Select the End Device Port WWN option.
b. Enter a port WWN in the End Device Port WWN field.
c. (Optional) Click the Assign Name check box and enter a name in the field.