Brocade Network Advisor SAN User Manual v12.0.0 (53-1002696-01, April 2013)

Brocade Network Advisor SAN User Manual 1215
53-1002696-01
Database tables and fields
H
PRESHARED_KEY The preshared key on tunnel. char 32
QOS_HIGH QoS high value. smallint
QOS_MEDIUM QoS medium value. smallint
QOS_LOW QoS low value. smallint
BACKWARD_COMPATIBLE Whether the 10G tunnel is backward compatible with
previous FOS versions.
smallint
FICON_TERADATA_READ_E
NABLED
Whether Ficon_Teradata_Read_Pipelining is enabled
on that tunnel.
smallint
FICON_TERADATA_WRITE_E
NABLED
Whether Ficon_Teradata_Write_Pipelining is enabled
on that tunnel.
smallint
TABLE 123 FCIP_TUNNEL_CIRCUIT
Field Definition Format Size
ID Unique generated database
identifier.
int
TUNNEL_ID Tunnel ID to which the circuit
belongs to
int
CIRCUIT_NUMBER Circuit Number of the Circuit
from the switch
smallint
COMPRESSION_
ENABLED
Whether Compression is
enabled on that circuit
smallint
TURBO_WRITE_
ENABLED
Whether TurboWrite is
enabled on that circuit'
smallint
TAPE_ACCELERATION_ENABLED Whether TapeAccelaration is
enabled on that circuit
smallint
IKE_POLICY_NUM The IKE Policy on the
circuit.The default value is -1.
int
IPSEC_POLICY_NUM The IPSEC Policy on the
circuit'. The default value is
-1
int
PRESHARED_KEY The preshared Key on the
circuit
char( 32
SOURCE_IP SOURCE_IP of the circuit varchar 64
DEST_IP DESTINATION_IP of the circuit varchar 64
VLAN_TAG VLAN Tag of the circuit. The
default value is -1
int
SELECTIVE_ACK Select acknowledgement
flag.The default value is 0.
smallint
QOS_MAPPING QOS Mapping.
The default value is 0.
smallint
PATH_MTU_DISCOVERY MTU Discovery Path.
The default value is 0.
smallint
TABLE 122 FCIP_TUNNEL (Continued)
Field Definition Format Size