Brocade Network Advisor SAN User Manual v12.0.0 (53-1002696-01, April 2013)
1088 Brocade Network Advisor SAN User Manual
53-1002696-01
Call Home Event Tables
B
TABLE 89 # Thermal Events
Event reason code FRU code/Event type Description Severity
800 DVP/LIM/HW High temperature warning. 3
801 DVP/LIM/HW Critically hot temperature warning. 3
802 DVP/LIM/HW Port card shutdown due to thermal violations. 3
805 SWM/SBAR/HW High temperature warning. 3
806 SWM/SBAR/HW Critically hot temperature warning. 3
807 SWM/SBAR/HW SBAR module shutdown due to thermal violations. 3
810 CTP/HW High temperature warning. 3
811 CTP/HW Critically hot temperature warning. 3
812 CTP/HW CTP shutdown due to thermal violations. 3
850 CTP/HW System shutdown due to CTP thermal threshold violations. 4
TABLE 90 Fabric OS Events
Event reason code FRU code/Event type Description Severity
N/A Ethernet Switch is not reachable. 3
N/A SW-Missing Switch is missing from the fabric. 3
1009 MS-1009 Error in registered link incident record (RLIR). 4
1402 FW-1402 Flash usage is out of range (Fabric OS version 6.0 or earlier). 3
1426 FW-1426 Faulty or missing power supply. 3
1427 FW-1427 Faulty power supply. 3
1428 FW-1428 Missing power supply. 3
1429 FW-1429 Problem in power supply arrangement. 3
1430 FW-1430 Faulty temperature sensors. 3
1431 FW-1431 Faulty fans. 3
1432 FW-1432 Faulty WWN cards. 3
1433 FW-1433 Faulty CPs. 3
1434 FW-1434 Faulty blades. 3
1435 FW-1435 Flash usage is out of range (Fabric OS version 6.1 or later). 3