TABLE 88 # CONSRV Events
Event reason code FRU code/Event type Description Severity
504 DVP/LIM/HW Port module failure. 3
506 DVP/PORT Fibre Channel port failure. 3
509 DVP/PORT Fibre Channel path failure. 0
511 LIM/DVP LIM SPP failure. 3
514 DVP/ LIM/PORT SFP/XFP optics failure. 3
517 LIM LIM SPP offline. 3
530 LIM/DVP LIM Power-up diagnostic failure. 3
536 LIM/DVP Internal Frame Error port anomaly - threshold exceeded. 2
604 SBAR/SWM/HW SBAR module failure. 3
607 SBAR/SWM/HW Switch contains no operational SBAR cards. 4
610 SWM/INFO SWM BMAC Link Down. 0
622 SBAR/INFO SWM powered off . 0
625 SBAR/INFO SWM NV RAM failure. 0