HP Application Recovery Manager software A.06.10 - Product announcements, software notes, and references (March 2008)
4 Recognized issues and
workarounds
This section lists known Application Recovery Manager and non-Application Recovery
Manager issues and workarounds.
Known Application Recovery Manager issues and
workarounds
Installation and upgrade related issues
• In case there is not enough free disk space on the destination partition, the push
installation of the User Interface fails and reports: [Warning] Installation
of User Interface FAILED! Application Recovery Manager
Software package installation failed Check the log file
/var/tmp/cc.pkgadd-log
Workaround: The disk space on the destination partition has to be at least 40
MB even if the package is installed on the linked partition.
• If the cluster client is configured under several virtual names, then Application
Recovery Manager Cell Manager will only update configuration information for
cluster virtual node.
Workaround: This has no effect on the actual state of the Application Recovery
Manager client - only configuration data is not upgraded. To finish the upgrade,
log to the Cell Manager system and run the command omnicc -update_host
virtual-name for every virtual name (other than cluster name).
• When installing Application Recovery Manager clients remotely in a cluster
environment, the Application Recovery Manager GUI allows you to push the
components to a virtual host, even though the components must not be added to
the virtual host.
Product announcements, software notes, and references 25