HP Application Recovery Manager software A.06.10 - Product announcements, software notes, and references (March 2008)

4 Recognized issues and
workarounds
This section lists known Application Recovery Manager and non-Application Recovery
Manager issues and workarounds.
Known Application Recovery Manager issues and
workarounds
Installation and upgrade related issues
In case there is not enough free disk space on the destination partition, the push
installation of the User Interface fails and reports: [Warning] Installation
of User Interface FAILED! Application Recovery Manager
Software package installation failed Check the log file
/var/tmp/cc.pkgadd-log
Workaround: The disk space on the destination partition has to be at least 40
MB even if the package is installed on the linked partition.
If the cluster client is configured under several virtual names, then Application
Recovery Manager Cell Manager will only update configuration information for
cluster virtual node.
Workaround: This has no effect on the actual state of the Application Recovery
Manager client - only configuration data is not upgraded. To finish the upgrade,
log to the Cell Manager system and run the command omnicc -update_host
virtual-name for every virtual name (other than cluster name).
When installing Application Recovery Manager clients remotely in a cluster
environment, the Application Recovery Manager GUI allows you to push the
components to a virtual host, even though the components must not be added to
the virtual host.
Product announcements, software notes, and references 25