HP Apollo a6000 Chassis Maintenance and Service Guide
Removal and replacement procedures 30
WARNING: To reduce the risk of electric shock or damage to the equipment:
• Do not disable the power cord grounding plug. The grounding plug is an important safety
feature.
• Connect the power cord into a grounded (earthed) electrical outlet that is easily accessible at
all times.
• Disconnect the power cord from the power supply to disconnect power to the equipment.
• Do not route the power cord where it can be walked on or pinched by items placed against it.
Pay particular attention to the plug, electrical outlet, and the point where the cord extends from
the chassis.
CAUTION: Do not operate the chassis for long periods with the access panel open or removed.
Operating the chassis in this manner results in improper airflow and improper cooling that can
lead to thermal damage.
Chassis procedures
This section provides removal and replacement procedures for chassis components.
Server blank
CAUTION: To prevent improper cooling and thermal damage, do not operate the chassis unless
all bays are populated with a component or a blank.
Remove the component as indicated.
To replace the component, reverse the removal procedure.
System fans
CAUTION: To avoid chassis shutdown, a fan must be replaced within 60 seconds of being
removed.