Ethernet SNMP Module Installation and Reference Guide ( J2603B) 1995-10
COunters [A/B/C/D]
To display network activity counters for each network port, the hub’s
SNMP agent, and the global count for all ports.
Total Packets The total number of packets and fragments received.
Collisions The number of times the port was involved in a collision. A single collision will be counted
by all ports involved, so the total collision count may be less than the sum of the port
counts.
CRC Errors The number of packets with invalid Cyclic Redundancy Checksums (CRCs). (The CRC is a
calculated value used to check the validity of each packet.)
Alignment Errors The number of incorrectly aligned packets.
Giant Packets The number of packets larger than 1518 bytes.
Broadcast Packets The number of packets addressed to station address FFFFFF-FFFFFF. A hub without an
HP Ethernet SNMP Module cannot count broadcast packets.
DIsconnect
To terminate the console session and reset the console port baud
rate to be automatically sensed. The command also disconnects the
phone link if you accessed the console using modems.
Extended Hub
Capabilities
Extended Hub Capabilities
2-13