HP StorageWorks 4x00/6x00/8x00 Enterprise Virtual Array Updating Product Software Guide XCS 6.110 (5697-6782, June 2007)

Figure 21 C ode Load Disk Drives Page 2 window
8. Click Ne
xt s te p.
The disk drive code load operation begins. A status page opens indicating the progress as each
disk drive is upgraded.
The disk drives are upgraded sequentially. Depending upon the I/O load on the storage system, it
can take 30 seconds to 3.5 minutes per drive to upgrade the rmware. The status is updated at 45
second i
ntervals, so you must wait to see which disk drives are complete.
CAUTIO
N:
If you s
elect any array in the Navigation pane to manage it, the disk drive upgrade stops.
For exa
mple, if 10 of 27 drives have completed the upgrade when you selected the array,
only th
ose 10 drives will be upgraded. If you run a second disk drive upgrade, the Status
box on
the Status window displays NO for the 10 d rives that have been upgraded and
the remaining 17 drives are not upgraded.
54
Upgrading the Enterprise Virtual Array