HP StorageWorks 4x00/6x00/8x00 Enterprise Virtual Array Updating Product Software Guide XCS 6.110 (5697-6782, June 2007)

If you installed the software suite on an SMA, the HP Command View EVA icon does not appear
on the desktop.
The software is available from the Start m enu (for example, Start > Programs > HP Command
View EV A).
If you installed the software suite on an SM A, the software is not available from the Start menu.
Go to Add/Remove Programs and m ake sure the applicable software components are listed:
HP StorageWorks Command View EVA software suite
HP StorageWorks Command View EVA
HP StorageWorks Command View EV A P erformance Monitor
•HPStorageWorksSMI-SEVA
•HPStorageWorksSMI-SCIMOM
NOTE:
HP Storage System Scripting Utility is not listed i n Add/Remove Progra ms.
2. Run HP Command View EVA.
3. Verify the display of storage system resources in the interface. In the Navigation pane, click
Hardware and verif y the following:
New, uninitialized arrays appear as uninitialized storage systems.
Previously initialized arrays appear with their previous names and correct status. (Select each
storage array to view the Properties window.)
Previous disk g roups, hosts, virtual disks, and other resources appear in the Navigation pane.
If information is not displayed properly, it may be necessary to congure your browser settings. See HP
StorageWorks Command View EVA installation gu ide for more i nformation.
Upgrading browsers and JREs
Estimated time to complete: 1020 minutes
When to per form: Any time prior to the upgrade
Ensure that you are using a supported browser and JRE. HP Command View EVA may not work correctly
with an unsupported browser.
The JRE is not used by HP Command View EVA, but it is needed for HP Replication Solutions Manager.
It is also required for WEBES and SAN Visibilit y. See " Upgrading HP Replication Solutions M anager
(optional)"onpage37formoreinformation.
For complete information on supported b rowsers and JREs, see the "Browsers and JRE suppor t" table in
the H P StorageWorks EVA software compatibility reference.See"Required documentation" on page 11
for the link to this d ocument.
NOTE:
If you need to update the browser version on remote computers, do so after you have upgraded to
HP Command View EVA 7.0.
Upgrading to WEB ES 5.0
Estim
ated time to complete: 1020 minutes
When to per form: Any time prior to the upgrade
HP StorageWorks 4x00/6x00/8x00 Enterprise Virtual Array updating product software guide XCS 6.110