HP StorageWorks 4x00/6x00/8x00 Enterprise Virtual Array Updating Product Software Guide XCS 6.110 (5697-6782, June 2007)

Upgrading HP Command View EVA,page33
Time required: 15 2 0 m i n u t e s
When to perform: Any time prior to the upgrade
Things you will need:
HP StorageWorks Command View EVA 7.0 installation media
Check the HP Command View EVA version.
Upgrade to version 7.0 if necessary.
Upgrading browser and Java Runtime Environment (JRE),page35
Time required: 10 20 minutes
When to perform: Any time prior to the upgrade
Upgrade brow
ser if necessary.
Upgrade JRE if necessary.
Upgrading to WEBES 4.5,page35
Time required: 10 20 minutes
When to perform: Any time prior to the upgrade
Things you will need:
WEBES 5.0 a n d upg rade documentation available from the following website:
h
ttp://h18023.www1.h p.com/support/svctools/webes/index.html?jumpid=reg_R1002_USEN
UpgradetoWEBES5.0ifnecessary
Upgrading HP Replication Solutions Man ager (optional), page 37
Time required: 10 20 minutes
When to perform: Any time prior to the upgrade
Things you will need:
HP StorageWorks Replication Solutions Manager 3.0
HP StorageWorks Replication Solutions Manager installation and administrator guide.See"Required
documentation"onpage11.
Upgrade to HP Replication Solutions Manager 3.0 if installed.
Monitoring storage system stability, page 37
Time required: 25–35 minutes
When to perform: 48 hours before the upgrade
Verify th
ere are no critical events entered in the controller event log.
Ensure the storage system conguration is stable and no conguration changes are in progress.
Preparing an HP Continuous Access EVA environment for upgrading, page 38
Time required: Varies depending on replication conguration
When to perform: As close as possible to the upgrade
Disable failsafe mode on all DR groups.
Back up all storage system data,page33
Time required: Varies
When to perform: As close as possible to the upgrade
Perform a full veried ba ckup of all storage system data.
Saving sto
rage system conguration information,page39
Time requi
red: 1015 minutes
When to per
form: As close as possible to the upgrade
Things you
will need:
HP Storag
e System Scripting Utility (called the utility). This is included with HP Command View EVA 7.0.
HP Storag
eWorks Storage System Scripting Utility reference.See"Required documentation"onpage11.
Capture conguration information using the utility.
Store co
nguration locally (not on storage system).
14
Pre-upgrade tasks