HP 4x00/6x00/8x00 Enterprise Virtual Array Release Notes (XCS 6.240) (5697-1059, June 2011)
Version:
XCS 6.240
Description
This document contains information specific to the release of XCS 6.240 for the EVA4000/6000/8000
and EVA4100/6100/8100. Much of the information included here is not documented elsewhere, so
it is recommended that you read this information thoroughly before installing and operating the
EVA4x00/6x00/8x00.
NOTE: If you are using asynchronous replication, HP strongly recommends that you upgrade to XCS
6.200 or later to ensure maximum performance.
Update recommendation:
Recommended
Product models
• EVA4000/6000/8000
• EVA4100/6100/8100
These arrays are referenced as EVA4x00/6x00/8x00 throughout the document.
Fixes
The following issues have been resolved in XCS 6.240:
• Addressed issues where inquiries to the Storage Array Control Device (SACD) or LUN 0 caused
a controller termination or returned invalid formed responses.
• Fixed a controller termination (termination code 0x0c210106,
SCID_DRM_GSN_OUT_OF_SEQUENCE_12) that occurred due to instability and deadlock issues
with DR group copies.
• Addressed issues with inconsistent persistent reservation commands when the array power was
cycled or the controllers were shut down.
• Fixed a resource allocation issue that could result in stalled virtual disks, CSM resets, or controller
resets for "kill other" terminations.
• Modified the failed disk processing routine to prevent a deadlock situation that can occur when
a disk drive fails during a controller mastership transfer.
• Fixed a controller termination (termination code 0x02050100, Invalid Unit Cache State) that
occurred when deleting a presented snapshot LUN.
• Fixed an issue with DR groups not coming online when delays occur during a source-directed
controller failover on the destination array in HP Continuous Access EVA configurations.
• Added a recovery routine to reduce the interruption of data availability when a disk drive fails
to properly log into the arbitrated loop.
• Fixed a controller termination that occurred when Fibre Channel Echo ELS commands are
received from a Fibre Channel switch that has not completed fabric login with the array.
• Addressed an issue in the controller software that led to incorrect capacity reporting when
ungrouping and grouping drives.
• Fixed a Unit Stalled Too Long (USTL) condition that occurred when the DR group log became full
while the array was running with one active controller.
• Fixed a rescursive controller termination (termination code 0x0443011f) that could occur in an
asynchronous HP Continuous Access EVA configuration after multiple attempts to complete a copy
over slow links.
Description 3