H3C LSW1FC4P0 Interface Card for S5820X-28C Ethernet Switches Installation Manual

27
4 Recovering an LSW1FC4P0 Card
Using Maintenance Mode
The LSW1FC4P0 card can become inoperable or unmanageable
for the following reasons:
Firmware becomes corrupt
IP address is lost
Configuration becomes corrupt
Password is forgotten
In these specific cases, you can recover the LSW1FC4P0 card
using maintenance mode. Maintenance mode temporarily returns
the interface card IP address to 10.0.0.1 and provides opportunities
to do the following:
Exit the maintenance menu (option 0)
Unpack a firmware image file in maintenance mode (option 1)
Reset the network configuration in maintenance mode
(option 2)
Reset user accounts in maintenance mode (option 3)
Copy log files in maintenance mode (option 4)
Remove the switch configuration in maintenance mode
(option 5)
Remake the file system in maintenance mode (option 6)
Reset the switch (option 7)
Update the boot loader in maintenance mode (option 8)
To recover the LSW1FC4P0 card, do the following:
1. Place the LSW1FC4P0 card in maintenance mode by pressing
and holding the Maintenance button with a pointed tool for
approximately 10 seconds. Release the button when both the
Power LED and the System LED are steady green.
2. Establish a Telnet session with the interface card using the
maintenance mode IP address 10.0.0.1.