H3C LSW1FC4P0 Interface Card for S5820X-28C Ethernet Switches Command Line Interface Guide Firmware Version 9.0.7

Command Reference
Capture
59272-00 C 141
Capture
Manages the data capture configuration for a specified Call Home profile. The
data capture configuration determines the time and frequency by which status and
trend data is collected from the switch and sent to recipients specified in the
profile.
Authority Admin session and a Callhome Edit session. Refer to the “Callhome” command
on page 11-136 for information about starting a Callhome Edit session.
Syntax capture
add [profile]
edit [profile]
remove [profile]
Keywords add [profile]
Adds data capture instructions to the profile given by [profile]. Table 5 describes
the data capture parameters.
edit [profile]
Opens an edit session in which to modify the data capture configuration for the
profile given by [profile]. Refer to Table 5 for a description of the data capture
configuration parameters.
remove [profile]
Removes the data capture configuration from the profile given by [profile].
Table 5. Data Capture Configuration Parameters
Parameters Description
TimeOfDay Time of day to send status and trend data to the
Tech_Support_Center profile e-mail recipients. The format is
hh:mm on a 24-hour clock. The default 02:00.
DayOfWeek Day-of-the-week to send status and trend data to the
Tech_Support_Center profile e-mail recipients. Values can be Sun,
Mon, Tue, Wed, Thur, Fri, Sat. The default is Sat.
Interval Number of weeks between capture data e-mails to the
Tech_Support_Center profile e-mail recipients. Values can be
1–26. The default is 1.