HP ProCurve Series 6120 Blade Switches Advanced Traffic Management Guide

6-26
Converged Enhanced Ethernet on the HP ProCurve 6120XG Switch
FIP Snooping
fip-snooping sessions show command
Figure 6-14. Output Displaying fip-snooping sessions show Command
fip-snooping FCF show command
Figure 6-15. Output Displaying fip-snooping FCF show Command
fip-snooping show Enode command
Figure 6-16. Output Displaying fip-snooping show Enode Command
Syntax: show fip-snooping sessions
Displays the fip-snooping session(s) information. Used to verify
if the Enodes are able to log into the fabric.
Default Value: None
Dependency: None
E-Node Int FCF MAC E-Node MAC VLAN FCoE MAC FC ID
---------- ------------- ------------- ---- ------------- -------
12 00059b-70f380 0000c9-934f3d 5 0efc00-410000 410000
Syntax: show fip-snooping fcf
Displays the fip-snooping FCF information.
Default Value: None
Dependency: None
Num. of
Port VLAN ID E-Nodes FC-MAP FCF MAC FCF Name Fabric Name
----- ------- ------- ------ ------------- --------------- --------------
24 5 1 0efc00 00059b-70f380 200500059b70f381 200500059b70f381
Syntax: show fip-snooping Enode
Displays the fip-snooping Enode details.
Default Value: None
Dependency: None
Port VLAN ID FCF Name FCF MAC FC ID
----- -------- ---------------- ------------- ------
12 5 200500059b70f381 00059b-70f380 410000