HP ProCurve Series 6120 Blade Switches Advanced Traffic Management Guide

6-16
Converged Enhanced Ethernet on the HP ProCurve 6120XG Switch
Data Center Bridging Exchange
Serious Errors
These errors indicate that something is misconfigured and will not function.
DCBX: port <port-num> serious mismatch (PFC). The configured
priorities for Priority Flow Control do not match on the neighbor. Ensure
that PFC is enabled on the same 802.1p priorities on the neighboring
device's connected port.
DCBX: port <port-num> serious mismatch (FCoE Priority). The
Application priority for FCoE does not match that of the neighboring
device’s connected port.
DCBX: port <port-num> multiple remote peers detected, only one
peer supported. This error message displays when multiple CNAs are
connected to one port via a hub or switch—this is an illegal configuration.