HP StorageWorks 4x00/6x00/8x00 Enterprise Virtual Array Updating Product Software Guide XCS 6.110 (5697-6782, June 2007)
Figure 28 Bad image header (Status code 65)
Solving problems if the storage system d oes not come back
online (Step 10)
The system software upgrade should take approximately 10 minutes to complete. If the storage system
does not come back within 10 minutes, check the following:
• Determine if the p roblem is with HP Command View EVA by perform ing the troubleshooting steps
in "HP Comm
and View EVA problems" on page 61.
• Check any WEBES messages.
1. Double click on the System Event Analyzer icon on the management server to run WEBES.
2. Click Full View under either System Log or the appropriate storage system in the left navigation
pane.
• Chec k the storage system event logs.
1. Run HP Command View EVA and log in.
2. Select t
he storage system whose logs you want to view.
3. Click View events to view the event logs that can be displayed.
If none of the above recommendations resolves the problem, contact your HP-authorized service
representative for help.
Solving problems with multiple resynchronizations (Step 10)
During the upgrade process, both controllers perform a resynchronization simultaneously. This invokes a
fast restart of the controllers — bypassing execution of lengthy hardware diagnostics. This fast restart
allows the controllers to complete the resynchronization sequence before the host timeout period elapses
and the host becomes aware that the stora ge system is unavailable.
If an event o ccurs that causes a second resynchronization while the firmware upgrade resynchronization
is still in progress, the controller will terminate with a code of 0b 08 01 00.Thefollowingevents
cause the controller to resysnchronize automatically:
• Initialization of the storage system
• Setting debug flags through the command line interface or OCP
• Occurrence of a disk group hardware problem on a Vraid1 virtual disk, or the return of a disk
during this condition
• Bad Block Replacement (BB R) per formed on a disk
• Memory allocation failure or other errors
Everyeffortshouldbemadetoensurenoneoftheseeventsoccurduringtheupgradeprocess. If
controller termination o ccurs due to multiple resynchronizations, contact your HP-authorized service
representative for assistance.
HP StorageWorks 4x00/6x00/8x00 Enterprise Virtual Array updating product software guide XCS 6.110
69