HP StorageWorks 4x00/6x00/8x00 Enterprise Virtual Array Updating Product Software Guide XCS 6.110 (5697-6782, June 2007)
NOTE:
The XCS firmwar e image file name has an extension of .sss.Thefile name contains the controller
model (200 for EVA 4x00 and EVA6x00 or 210 for EVA8x00) and the XCS version. For example,
210_6100.SSS is the name of the XCS 6.110 file for the HSV210 controller.
Invalid firmware image file (Status code 21006)
If the XCS firmware image file is the wrong image, an Operation failed message is displayed. See Figure
27.ClickOK to return to the Initialized Storage System Properties window.
Figure 27 Invalid firmware image fil e (Status code 21006)
Bad image header (Status code 65)
HP Command View EVA sends the XCS controller fi rmware to the controller in segments. As each
segment is received, it is validated by the controller. HP Command View EVA monitors each segment
transfer and displays the transfer status information.
If a problem occurs, the process stops and HP Command View EVA displays the segment transfer that
was not successful. This is typically caused by a problem in the XCS controller firmware image file or the
selection of the wrong fi rmware image file. See Figure 28. If this error oc curs, do the following:
1. Click OK to return to the Initialized Storage System Properties window.
2. Click Code load to begin the code load sequence again.
3. Ensure that you select the correct firmware image file, and continue the process.
If the process fails again with the same message, d ownload the firmware image file again and repeat
the p rocess.