HP StorageWorks 4x00/6x00/8x00 Enterprise Virtual Array Updating Product Software Guide XCS 6.110 (5697-6782, June 2007)
Resolution
Table 11 Possibl
e causes and corrective actions for HTTP 404 and HTTP 503 errors
Possible Cause
Corrective Action
404 Error: HP Command View EVA may be initializing
when a browser makes a request. The web returns a 404
(Page Not Found) error because it cannot get the page.
Retrytherequestbyclickingthe
Refresh/Reload button on the browser.
404 Error: A .frm (HTML) file may be missing in the HP
Command View EVA directory structure. This can occur
if the fileswerechangedoriftheHPCommandView
EVA installation went amiss.
Reinstall HP C
ommand Vi ew EVA.
503 Error: HP Command View EVA may be down when
a browser makes a request. The web server returns a 503
(No Service) error because it cannot access the page.
Retr y the request when HP Command View
EVA is up .
Browser timeout: The appliance may be down or the
web server may be unavailable when a browser makes
arequesttoHPCommandViewEVA.Inthiscase,the
browser will time out internally.
Retry the request when the appliance and
HP Command View EVA are up.
Unknown storage system
Symptom
HP Command View EVA reports an unknown storage system for a storage system that should be
displayed.
Cause of the error
HP Command View EVA may have lost communication with the controllers. Two possible scenarios are:
• The HBA in
the management server m ay have timed out commands to the controllers. See
"Unknown storage sy stem—cause 1" on page 64 below.
• The controllers are running a version of XCS that HP Command View EVA does not recognize.
See "Unk
nownstoragesystem—cause2" on page 64.
Unknown storage system—cause 1
When the fabric is heavily loaded, the FC adapter in the management server may time out com m ands to
the controllers. If this occurs, the storage system appears in the Unknown state.
Corrective Action for Unknown Storage System—Cause 1
This scenario should correct itself in less than one minute. Alternately, you c a n perform a Rediscover
operation to initiate new commands to the controller.
Unknown storage system—cause 2
HP Comm
and View EVA can only manage controllers that are running supported XCS versions.
Correc
tive Action for Unknown Storage System—Cause 2
Ensure that you are running the HP Command View EVA version that is compatible with XCS 6.110. See
the “EVA software version compatibility” table in the HP StorageWorks EVA software compatibility
reference to determine which version of HP Command View EVA you should be running. Then, upgrade
HP Command View EV A to a compatible version . See "Required documentation"onpage11forthe
link to this document.
64
Troubleshooting