HP StorageWorks 4x00/6x00/8x00 Enterprise Virtual Array Updating Product Software Guide XCS 6.110 (5697-6782, June 2007)
Figure 16 Initializing firmware code load
Figure 17 St orage system updating firmware
11 . When the firmware upgrade is complete, the Initialized Storage System Properties window opens.
Verify the version of the storage system software in the Version box. It should be 6110.
Figure 18 Verifying XCS version after upgrading
Step 6. Upgrading disk drive firmw are
Estimated time to complete: Varies depending on the number of disk drives that require upgrading and the
I/O load on the storage system. It can take 30 seconds to 3.5 minutes per drive to upgrade the firmware .
Updated disk drive firmware is included with each XCS release. The firmware on all disk drives can
be upgraded online.
Although it is not required that the disk drive firmware be upgraded at the same time as the system
software, it is strong ly recommended that you per form the two tasks together. The disk drive firmware
supplied with the system software upgrade complements the operation of the controller firmware and for
the best results the two should be used together.
HP StorageWorks 4x00/6x00/8x00 Enterprise Virtual Array updating product software guide XCS 6.110
51