HP StorageWorks 4x00/6x00/8x00 Enterprise Virtual Array Updating Product Software Guide XCS 6.110 (5697-6782, June 2007)
Table 9 XC S 6.110 System Software Upgrade Checklist
Step 1. Checking the health of the Enterprise Virtual Array,page42
Time required: 20–30 minutes
HP Command View EVA indicates no hardwa re problems
No hardware components in the Unmappable Hardware folder
No critical events entered in the controller event l og within the last 48 hours
Storage syste
mconfiguration is stable and no configuration changes have been made within the last 48
hours
Step 2. Disabling ISEE, page 45
Time required: 10 –15 minutes
Disabl e ISEE (if used).
Step 3. Clearing storage system passwords, page 46
Time required: 10 –15 minutes
Clear the OCP password.
Disable password access in HP Command View EVA.
Step 4. Haltin
g all host access to the storage system for an offline upgrade (optional),page47
Time required: Varies by host. Must be performed for each host accessing the storage system
Halt all applications accessing the storage system.
Stop all I/O t
othestoragesystem.
Step 5. Upgrading controller firmware to XCS 6.000, page 47
Time required: 25–30 minutes
Things you will need:
• HP StorageWorks EVA 4x00/6x00/8x00 6.1 controller software
Upgrade XCS firmware to version 6.110.
Step 6. Upgrading disk drive firmware, page 51
Time required: Varies depending on the number of disk drives that must be upgraded. It can take 30 seconds
to 3.5 minutes per drive.
Things you will need:
• Disk drive code bundled image file, which can be downloaded from the following website:
h
ttp://www.hp.com/support/evadiskfirmware
Download the disk drive firmwar e file.
Upgrade the disk drive firmware.
Step 7. Ente
ring storage system passwords,page56
Time requir
ed: 10–15 minutes
Enter the O
CP password.
Enable pas
sword access in HP Command View EVA.
Step 8. Resuming storage system operation, page 57
Time required: Varies
Restart applications accessing the storage system if an offline upgrade was performed.
WhenrunningHPContinuousAccessEVA,enablefailsafemodeonallDRgroups.
If you changed any host LUN timeout values, reset them to their original values.
Enable ISEE (if used).
Step 1. Checking the health of the Enterprise Virtual Array
Estimated time to complete: 20–30 minutes
42
Upgrading the Enterprise Virtual Array