HP StorageWorks 4x00/6x00/8x00 Enterprise Virtual Array Updating Product Software Guide XCS 6.110 (5697-6782, June 2007)
• Before you upgrade any storage system in an HP Continuous Access EVA relationship, ensure that
all storage systems in the storage net work are running the same version of c ontroller software.
This will ensure that when you upgrade one storage system, the storage network will have only
two versions of c ontroller software. You cannot have more than t wo versions in an HP Continuous
Access EVA envir onment.
• During the time that the HP Continuous Access EVA storage systems are running different controller
software versions, you cannot make any configuration changes to your storage systems.
• You must perform the necessary upgrades to the storage systems in the HP Continuous Access
EVA relationship within one week (168 hours) to make all controller software versions the same.
CAUTION:
In an HP Continuous Access EVA environment, do not begin the upgrade until the following conditions
are met. If you attempt to upgrade the controllers before the following conditions are met, controller
operation will fail.
• Ensure that no DR group is logging, merging, or copying. Furthermore, none of the DR groups can
be in a failsafe locked state.
1.
ClicktheDRgroupiconintheNavigationpane.
2.
Check the Log state in the DR Group Properties window.
• Ensure the connection between the storage sy stems is not compromised or failed.
1.
Click the Da ta Replication folder in the Navigation pane.
2.
Check the Connection State in the Data Replication Folder Pr operties window.
• All EVA storage systems must be running normally with fully functio nal controller pairs.
• After upgrading the firststoragesystem(forexample,thesource),waitatleastthreeminutesandno
morethanoneweekbeforeupgradingthesecondstoragesystem.Ensuretheprecedingconditions
aremetonthesecondsystem.
Upgrading disk drive firmware in an HP Continuous Access EVA environment
When upgrading disk drive firmware in an HP Continuous Access EVA en vironment, the following
requirements must be met. See HP StorageWorks Continuous Access EVA administrator guide for more
information.
• Suspend the intersite link and upgrade all drives on the destination storage system.
• Resume the intersite link and allow the merge to complete.
• Perform site failover.
• Suspend the intersite link again a n d upgrade all drives on the new destination storage system.
• Resume the intersite link and allow the merge to complete.
• Perform site failback.
Saving storage system configuration information
Estimated time to complete: 10–15 minutes
When to perform: A s close as possible to the upgrade
Before beginning the upgrade, the current c onfiguration information should be collected and saved. This
inform ation can be used to restore the existing configuration if necessary. The configuration data is saved
to a series of files stored in a loca tion other than on the storage system. HP Storage System Scripting
Utility (called the utility) is used to collect configuration information.
This procedure can be per formed from the Storage Management Appliance (SMA) or management
server where HP Command View EVA is installed, or from any host running the utility to communicate
with the H P Command View EVA.
HP StorageWorks 4x00/6x00/8x00 Enterprise Virtual Array updating product software guide XCS 6.110
39