HP StorageWorks 4x00/6x00/8x00 Enterprise Virtual Array Updating Product Software Guide XCS 6.110 (5697-6782, June 2007)
2. Click Yes to run the kit.
The k it does the following:
a. Saves configuration and state data to %SystemDrive%:\WebesBackup,where
%SystemDrive% is the drive where Windows (not ne cessarily WEBES) was installed.
b. Uninstalls the ex isting installation.
c. Installs this version with the same components (SEA or CCAT) that were present b efore.
d. Restores the saved data.
e. Deletes the WebesBackup directory and all of its contents.
Upgrading HP Replication Solutions Manager (optional)
Estimated time to complete: 10–20 minutes
When to per fo
rm: Any time prior to the upgrade
If HP Replica
tion Solutions M anager is installed, you must upgrade it to version 3.0. HP Replication
Solutions M
anager is an optional interface for HP Business Copy EVA and HP Continuous Access EVA.
For install
ation information, see the HP StorageWorks Replication Solutions Manager installation guide.
For general
usage information, see the HP StorageWorks Replication Solutions Manager administrator
guide.See"Required documentation"onpage11.
HP Replication Solutions Manager can be downloaded from the following website:
h
ttp://h18006.www1.hp.com/products/storage/software/bizcopyeva/index.html
Click Software & drivers.
NOTE:
HP Replication Solutions Manager 3.0 requires JRE 1.5.0_04 and later. Go to the Sun website
(w
ww.sun.
com) and download the require d JRE.
Monitor ing stor age s ystem stability
Estimated time to complete: 25–30 minutes
When to perform: 48 hours b efore beginning the upgrade
The storage system configuration should be stable for 48 hours before beginning the upgrade. Check the
status of the array to ensu re it is stable and then continue m onitoring status until the upgrade begins.
1. Open HP Command View EVA and click the icon of the storage system you want to upgrade.
2. Using HP Command View EVA, examine the controller event log and check for any critical events.
a. Select the icon of the storage system you want to upgrade in the Navigation pane.
b. Click View Events.
TheViewEventswindowopens.
c. Click Controller Event Log.
The Controller Events window opens in a new browser window.
HP StorageWorks 4x00/6x00/8x00 Enterprise Virtual Array updating product software guide XCS 6.110
37