HP StorageWorks 4x00/6x00/8x00 Enterprise Virtual Array release notes (XCS 6.200) (5697-0024, May 2009)

Changing storage system cable connections on a C-series switch
If it becomes necessary to move the storage system Fibre Channel cable to a different port on a
C-series switch, or to a port on a different C-series switch, the corresponding controller host port will
become unavailable.
If this situation occurs, it will be necessary to restart the controller to restore host post operation. This
can be done from HP Command View EVA as follows:
1. Open HP Command View EVA and click the icon of the appropriate storage system. You can
select either an initialized or unintialized storage system.
2. On the Initialized Storage System Properties page, click Shut down.
3. Under Controller Shutdown, select the appropriate controller (A or B) for restart.
4. Click Restart.
The controller is restarted. At the conclusion of the restart the host port should be operating
normally.
C-Series MDS 9020 switch and HP Continuous Access EVA
The C-Series MDS 9020 switch is only supported with HP Continuous Access EVA when the EVA is
running XCS 6.000 or later.
Microsoft Windows MPIO/DSM 3.00.00 is recommended
HP recommends that you upgrade to Windows MPIO/DSM (Device Specific Module) version 3.00.00,
which provides the read optimization feature, for XCS 6.100 or later. The read optimization feature
enables all read requests to be sent to one controller and avoids potential performance impacts due
to proxied read requests. The minimum supported version is 2.00.02.
You can download MPIO/DSM 3.00.00 from the following website:
http://h18006.www1.hp.com/products/sanworks/multipathoptions/index.html
1. Select Browse by capacity or operating system.
2. Under Browse by OS, select Microsoft Windows.
3. Under FREE Integrations, select Multi-Pathing IO (MPIO) Device Specific Modules.
4. Select Windows MPIO DSM for EVA.
5. Select the appropriate Windows operating system.
6. Select HP MPIO Full Featured DSM for EVA4x00/6x00/8x00 families of Disk Arrays.
See the HP MPIO Full-Featured DSM for EVA Disk Arrays release notes for more information. The
release notes are included in the download file.
HP Continuous Access EVA configurations between XCS 6.200 and VCS 3.110
The following issues are known to affect HP Continuous Access EVA configurations between XCS
6.200 and VCS 3.110:
DR log size cannot be changed
Auto-Suspend option is disabled
12