HP StorageWorks 4x00/6x00/8x00 Enterprise Virtual Array hardware configuration guide (5697-7338, February 2008)
EVA8x00 HSV210
-A/B controllers
Two high-perf
ormance HSV210 controllers are included in each EVA8x00 rack. The EVA8000 controller
is identified a
s HSV210-A and the EVA8100 controller is identified as HSV210-B. Each controller is
contained in a separate enclosure and provides the following features:
• High-performance PowerPC microprocessor
• An Operator C
ontrol Panel (O CP) for easy operation
• 4U rack space required for both controller enclosures
• Four 4–Gbps Fibre Channel-Switched Fabric host ports
• Four 2–Gbps
FC-AL device ports
• Arranged in redundant pairs
• Data load/performance balanced across a pair
• Supports up
to 240 disks (120 disks per pair)
• 2 GB cache per controller, mirrored, with b attery backup
• 2 Gbps FC cache mirroring port with device port backups
• Two mirror
ports
• Dual power supplies
The controller is the interface between HP StorageWorks Command View EVA and the Enterprise
Virtual Array (the interface between hosts and disks). Up to 18 drive enclosures are supported by
one HSV21
0-A/B controller pair (two controllers).
Figure 4 shows the front of the controller. Figure 5 shows the controller rear view.
1
2
3
4
6
5 7
6
4
Figure 4 HSV210/200 controller—front view
1. Battery 0
2. Batter y 1 (EVA8x00 only)
3. Blower 0 4. Blower 1
5. Operator Control Panel (OCP) 6. Status indicators
7. Unit ID
16
EVA 4x00/6x00/8x00 hardware