Medical Archive Solutions User Guide
HPMA User Guide
188
HP Medical Archive
PTEn Temperature State; an indication of the
temperature status, summarizing the
RAID temperature situation:
• 0=OK
• 1=Temp Low
• 2=Temp High
• 3 = Critical
• 4 = Unavailable
The letter n in the Attribute Code is an
indicator of which RAID, as some servers
are attached to multiple RAID units.
There may be some issues with the
cooling around the servers, and
measures should be implemented
to help keep the servers cool or to
investigate if the temperature is
too low.
RMS1 RAID Monitor Status. This is an overall
indication of whether the RAID monitor
driver is connecting with the SSM service:
• 0=Connected
• 1 = Connecting...
• 2 = Disconnected
A status of “Disconnected” does not mean
that the RAID is faulty, only that the SSM
is unable to monitor it.
If the monitor is “Disconnected”
for an extended period, restart the
server. If this does not clear the
problem, contact HP technical
support.
RSTU FSG Replication status; whether the com-
ponent is:
• 0=Normal
• 1=No Primary
• 2=Error
If the device reports “No Pri-
mary”, ensure the primary FSG
service of the replication group is
online and running normally. If
the status is “Error”, contact HP
technical support.
SAVP Space Available; the percentage of storage
space remaining on all object stores of the
server.
Adjusting the alarm threshold allows you
to proactively manage when additional
storage needs to be purchased.
If the available space is reaching a
low threshold, you should start
looking into either purchasing
additional storage or migrating
some data to archive, depending
on your available options.
Attr.