HP B-series Network Advisor Enterprise, Professional Plus, and Professional 11.1.2 Release Notes (5697-1433, December 2011-includes all 11.1.x versions)

Table 7 HP Network Advisor 11.1.0 closed defects
SolutionClosed fixes summary
Fixed in HP Network Advisor 11.1.0.Brocade Access Gateway (AG) switches running Fabric OS 5.3 were not
shown in DCFM and an inappropriate message was shown when trying to
rediscover the fabric.
Fixed in HP Network Advisor 11.1.0.Master log reports port number and port index as one greater than actual
value.
Fixed in HP Network Advisor 11.1.0.DCFM server runs out of memory when managing HP StorageWorks SAN
Director 2/128 or HP StorageWorks 4/256 SAN Director switches for
several weeks.
Fixed in HP Network Advisor 11.1.0.Server backup fails to authenticate with Network drive after a server reboot.
Fixed in HP Network Advisor 11.1.0.The twelfth character of a LUN Serial Number (LSN) is getting dropped on
some paths in the Encryption Disk LUN View.
Fixed in HP Network Advisor 11.1.0.Master Trunk ports in product tree and connections between AG and a
switch are not shown properly when F_Port trunking is enabled on the AG
setup.
Fixed in HP Network Advisor 11.1.0.Remote VE_Port WWN is shown as missing and with a red icon under end
devices.
Fixed in HP Network Advisor 11.1.0.Fault Management “VFID” is shown as “Chassis for “Switch name change
event” in the master log.
Fixed in HP Network Advisor 11.1.0.There are yellow dotted lines shown between the segmented switch and
the End Device in the re-discovered fabric.
Fixed in HP Network Advisor 11.1.0.In the Client, IFL/ISL connections are not being displayed correctly in the
topology view when multiple circuits are added with different GigE ports
for a tunnel.
Fixed in HP Network Advisor 11.1.0.For zoning, sorting of ports is not accurate in the Hex display mode for the
user port number.
Fixed in HP Network Advisor 11.1.0.In the Client, the latest topology changes are not reflected; the yellow dotted
line is not shown when the tunnel is deleted.
Fixed in HP Network Advisor 11.1.0.In the Device Tree, on selecting an E_Port on switch1, after 1 minute focus
changes to the same port under switch-2, and is misleading to the user.
Fixed in HP Network Advisor 11.1.0.When a user attempts to delete a logical switch the operation may fail with
the error message internal server error.
Workaround prior to upgrade: Close and
reopen the circuit dialog on different
circuits to perform the edit operation.
A user is unable to edit the commit rate of a second circuit after the first
circuit has been modified without closing and reopening the FCIP Tunnel
dialog box.
Fixed in HP Network Advisor 11.1.0.
Fixed in HP Network Advisor 11.1.0.In the Client, the Logical Switch Sequence Number is displayed incorrectly
in the Switch Properties Dialog.
Fixed in HP Network Advisor 11.1.0.In Port Fencing, Switch-level Alert was missing when a port is fenced for
Link reset violation type.
Workaround prior to upgrade: Change
commit rates on both the local and remote
FCIP Circuits do not come up and stay in an 'In progress' state after
changing the commit rate.
ends separately through the CLI if there
are different VLAN tags at both ends.
Fixed in HP Network Advisor 11.1.0.
Workaround prior to upgrade: Hit the
refresh button in the target dialog to see
the hosts configured.
At times hosts are not displayed and a user will not be able to view the
LUNs configured for a container.
Fixed in HP Network Advisor 11.1.0.
18