HP B-series Fabric OS 7.1.0c Release Notes (5697-2892, October 2013 - includes all 7.1.0x versions)

Table 9 Fabric OS 7.1.0 closed defects (continued)
SolutionClosed defect summary
Fixed in Fabric OS 7.1.0.FICON emulation is not handling IU pacing updates
properly. Aborts occur on the fabric with an HP 400
Multi-protocol Router and the application fails.
Fixed in Fabric OS 7.1.0.In Fabric OS 7.0 and later, a name server request "RFT_ID"
for several NPIV ports are rejected with reason 0x05
(Logical Busy) and the host cannot see the device if it does
not retry the request.
Fixed in Fabric OS 7.1.0.On HP SN6000B 16Gb FC Switch, the portledtest
-action option does not display the LED pattern
documented in the help page.
Workaround prior to upgrade:The device is not failing over to its alternate port if that
alternate port happens to be on the upper part of the HP
Use port indexes 239-254.
DC SAN Director 64-port 8Gb FC Blade such as port
indexes 868 to 884.
Fixed in Fabric OS 7.1.0.
Fixed in Fabric OS 7.1.0.Ports LEDs do not flash on 16Gb/s switches during the
portloopback.
Fixed in Fabric OS 7.1.0.Unable to create a CSR file using the command
seccertutil when IPV6 is configured.
Fixed in Fabric OS 7.1.0.A failure occurs when running 'portledtest -npass 10',
'portloopbacktest -lb_mode 1' test.
Fixed in Fabric OS 7.1.0.SNMP crashes while generating core files and then fails
to restart.
Workaround prior to upgrade:The userconfig --change command on the HP
SN8000B SAN Directors running Fabric OS 7.0.1 displays
glibc detected, invalid pointer error.
Manually delete and recreate the user via CLI.
Fixed in Fabric OS 7.1.0.
Fixed in Fabric OS 7.1.0.WebTools function logged in using the User profile displays
the CSCTL option as bold and is functional, but the
dropdown list does not show any bolded options.
Workaround prior to upgrade:FCIP Emulation does not release aborted exchanges,
potentially causing generated SCSI Busy status sequences
if the exchange is reused within 22 seconds.
Disable the FCIP emulation.
Fixed in Fabric OS 7.1.0.
Workaround prior to upgrade:When users perform portloopbacktest repeatedly
on the HP 8/80 SAN Switch running Fabric OS
Avoid running portloopbacktest in loop.
7.0.1/7.01a in a loop script, even though the repeated
Fixed in Fabric OS 7.1.0.
tests complete with a "PASSED", the switch moves to a
faulty status.
Workaround prior to upgrade:The Onboard Administrator incorrectly reports the
management IP address for the Brocade 8Gb SAN Switch
Reboot the switch after the firmware download.
for HP BladeSystem c-Class when using DHCP. It is shown
as 0.0.3.0 after upgrading to Fabric OS 6.4.0 and later.
Fixed in Fabric OS 7.1.0.
Fixed in Fabric OS 7.1.0.Users may notice slow performance when running a script
with many commands. However, individual command
response time is still within seconds.
Workaround prior to upgrade:The HP SN8000B SAN Directors standby CP panics after
running system verification when they are fully populated
with HP DC SAN Director 64-port 8Gb FC Blades.
Remove one of the HP DC SAN Director 64-port 8Gb FC
Blades for system verification to pass without any issue.
Fixed in Fabric OS 7.1.0.
Fabric OS 7.1.0 fixes 55