HP B-series Fabric OS 7.1.0c Release Notes (5697-2892, October 2013 - includes all 7.1.0x versions)

Table 9 Fabric OS 7.1.0 closed defects (continued)
SolutionClosed defect summary
Fixed in Fabric OS 7.1.0.The perfhelp command output does not include
information on the fmconfig command.
Fixed in Fabric OS 7.1.0.In Fabric OS 7.0.0b and earlier (that use OpenSSL
0.9.8d), vulnerability scanning tools may report the
presence of CVE-2009-3245.
Workaround prior to upgrade:Shared memory segments are used up by the Name Server
and users are unable to manage switch.
Avoid running the nsaliasshow command.
Fixed in Fabric OS 7.1.0.
Workaround prior to upgrade:AG may sometimes not show up in agshow and F-ports
are unable to login.
Execute a reboot switch, not an HA Reboot.
Fixed in Fabric OS 7.1.0.
Fixed in Fabric OS 7.1.0.CRC with good EOF detected on ICL ports between and
HP DC SAN Backbond Director and an HP DC04 SAN
Director.
Fixed in Fabric OS 7.1.0.There are missing blocks on tapes when tape pipelining is
enabled.
Fixed in Fabric OS 7.1.0.There is an FCIP tunnel performance drop when running
Fabric OS 7.x.
Fixed in Fabric OS 7.1.0.There is a POST failure with misleading test name on 16
Gb/s blades.
Fixed in Fabric OS 7.1.0.FICON Selective resets occur during sort tape job with
large channel programs when running through FICON to
ESCON converter and FCIP FICON Tape Pipelining.
Fixed in Fabric OS 7.1.0.Entering incorrect WWPNs or WWNNs for creating CTCs
will cause a panic on an HP Encryption SAN switch.
Fixed in Fabric OS 7.1.0.A switch may report duplicate WWN and panic.
Fixed in Fabric OS 7.1.0.The diagshow output for the HP 2408 FCoE Converged
Network Switch incorrectly displays 10 Gb/s ports.
Fixed in Fabric OS 7.1.0.A switch panic may occur upon detection of SRAM parity
errors on the HP 400 Multi-protocol Router and the HP
B-Series Multi-protocol Router Blade.
Fixed in Fabric OS 7.1.0.C2-1006 and C2-1010 error messages are displayed
reporting internal link errors without any hardware fault.
The issues are linked with Good EOF CRC errors associated
with SERDES tuning for HP DC Switch Encryption FC Blade
inserted in slot 12 of an HP DC SAN Backbone Director
and HP SAN Director 16-port 8Gb FC Blades inserted in
slots 1,2,7 on an HP DC04 SAN Director.
Fixed in Fabric OS 7.1.0.DP Panic may occur with 3900 type printers when FICON
printer emulation is enabled.
Fixed in Fabric OS 7.1.0.The agshow command is missing from supportshow
and supportsave commands.
Fixed in Fabric OS 7.1.0.A stale AG entry may remain in the management server
database after the removal of AG.
Workaround prior to upgrade:The HP Encryption SAN Switch may be unable to connect
to any of the TKLMs.
Reboot the HP Encryption SAN Switch.
Fixed in Fabric OS 7.1.0.
Fabric OS 7.1.0 fixes 53