HP B-series Fabric OS 7.1.0c Release Notes (5697-2892, October 2013 - includes all 7.1.0x versions)
Table 9 Fabric OS 7.1.0 closed defects (continued)
SolutionClosed defect summary
Fixed in Fabric OS 7.1.0.A Linux kernel module load bug causes a switch panic.
The sloterrshow and ptbufshow commands display
an invalid credit value for the longdistance link.
Fixed in Fabric OS 7.1.0.The sloterrshow and ptbufshow commands display
an invalid credit value for the longdistance link.
Fixed in Fabric OS 7.1.0.In a FICON environment, there are dropped frames during
a non-disruptive firmwaredownload with open systems
traffic.
Fixed in Fabric OS 7.1.0.The error message for a duplicate user assigned FAPWWN
will show the slot/port as -1/-1 if the port is in a different
logical switch.
Fixed in Fabric OS 7.1.0.The switch name is blanked out when FMS mode is enabled
for the first time.
Fixed in Fabric OS 7.1.0.The HP Encryption SAN switch does not perform a LOCATE
to the correct position after PI does a PLOGI/PRLI during
a restore.
Fixed in Fabric OS 7.1.0.Firmwaredownload fails on Co-CPU of a standby CP.
Fixed in Fabric OS 7.1.0.If a number of rwmonitors are created for a particular port
using the perfaddrwmonitor command and the monitors
are deleted, in some situations the perfcfgrestore
does not restore all of the monitors previously created.
Fixed in Fabric OS 7.1.0.During HA Failover, if there are too many timed-out and
un-routable frames being forwarded to the CPU, there is
potential for a port to lose credits.
Fixed in Fabric OS 7.1.0.A stuck VC detection is being intermittently delayed in the
bottleneck detection feature.
Fixed in Fabric OS 7.1.0.Commands continue running when telnet/SSH session ends
abruptly.
Fixed in Fabric OS 7.1.0.Software 'verify' error is detected when portstatsshow
is executed with an invalid index (999) and the -f option.
Fixed in Fabric OS 7.1.0.The security vulnerability check for CVE-2011-3192 fails
on switches running Fabric OS versions earlier than 7.0.2.
Fixed in Fabric OS 7.1.0.An F_Port is stuck in Disabled (N-Port Offline for F-Port)
after an AG reboot.
Fixed in Fabric OS 7.1.0.The CLI command portCfgFillWord (C, F, W in upper
case) command returns "exec error: 2, No such file or
directory".
Fixed in Fabric OS 7.1.0.Management ports go down after a code upgrade.
Fixed in Fabric OS 7.1.0.When trying to replicate only SNMP settings from one
switch to another switch using Network Advisor, AAA
settings are also being replaced.
Fixed in Fabric OS 7.1.0.F_Port trunk area configuration may be lost in switches
when upgrading to Fabric OS 6.4.x.
Workaround prior to upgrade:Users may not see the port/blade selection on the port
throughput, port error and blade aggregate throughput
graphs.
Users can manually enter the port number in the slot, port
format to display the desired graph. For blade aggregate
throughput, manually entering just the slot number will
display the appropriate graph.
Fixed in Fabric OS 7.1.0.
Fabric OS 7.1.0 fixes 51