HP B-series Fabric OS 7.1.0c Release Notes (5697-2892, October 2013 - includes all 7.1.0x versions)

Table 9 Fabric OS 7.1.0 closed defects (continued)
SolutionClosed defect summary
Workaround prior to upgrade:A kernel panic occurs during upgrade to Fabric OS 6.4.3
and 7.0.1b or later.
Avoid any discovery frames during
HA/firmware-download.
Fixed in Fabric OS 7.1.0.
Workaround prior to upgrade:An abort received from the Channel immediately after
starting FICON Tape Read Pipelining.
Disable FCIP FICON tape read pipelining.
Fixed in Fabric OS 7.1.0.
Fixed in Fabric OS 7.1.0.Boot over SAN may have an 8 second delay when the
target device is not on the local switch.
Workaround prior to upgrade:The HTTPD (Apache server 1.3.31-10) goes to a defunct
state, causing loss of manageability by Network Advisor.
Restart the httpd or perform an Ha Failover.
Fixed in Fabric OS 7.1.0.
Workaround prior to upgrade:FICON IFCCs for extended Emulated Printer sequences
during Unit Check Processing.
Disable FICON printer emulation.
Fixed in Fabric OS 7.1.0.
Fixed in Fabric OS 7.1.0.CRC with Good EOF errors detected on the HP DC SAN
Backbone Director on 5/139 link when an HP SAN
Director 32-port 8Gb FC Blade is installed in slot 3 and
on 5/100 link when an HP DC SAN Director Multiprotocol
Extension Blade is installed in slots 4.
Workaround prior to upgrade:“HTTP error:: Fatal connection error” is displayed when
changing the port configuration policy while in AG mode.
Use the AG CLI to configure the AG port policy.
Fixed in Fabric OS 7.1.0.
Fixed in Fabric OS 7.1.0.EE monitors in VF environments with duplicate PID/SID on
the same ASIC do not function properly.
Workaround prior to upgrade:On the HP 8/8 SAN Switch, HP 8/24 SAN Switch, and
the HP 8/80 SAN Switch the Hardware tool shows the
Run portdisable CLI on ports without POD licenses.
SerDes are still on and generating signals on ports without
a POD license, causing an EMI issue.
Fixed in Fabric OS 7.1.0.
Fixed in Fabric OS 7.1.0.A director switch became non-responsive from all access
methods with a possible CPU overload.
Workaround prior to upgrade:The fmmonitor --show -port command does not
work for a range of ports.
Run fmmonitor --show on individual ports.
Fixed in Fabric OS 7.1.0.
Fixed in Fabric OS 7.1.0.The CP in slot 6 of an HP DC04 SAN Director with HW
error interrupts results in CP kernel panic with Oops: kernel
access of bad area, sig: 11.
Fixed in Fabric OS 7.1.0.There is an inappropriate numerical value of Logical port
displayed by Webtools(SAM Report) on the HP 8/40 SAN
Switch running Fabric OS 6.3.2.e1.
Fixed in Fabric OS 7.1.0.A switch drops ADISC requests from a third-party HBA.
Fixed in Fabric OS 7.1.0.When executed on an HP SN6000B 16Gb FC Switch/HP
SN3000B 16Gb FC Switch, the portloopbacktest command
always uses 16 Gb mode, regardless of the port speed
specified.
Fabric OS 7.1.0 fixes 59