HP B-series Fabric OS 7.1.0c Release Notes (5697-2892, October 2013 - includes all 7.1.0x versions)
Table 9 Fabric OS 7.1.0 closed defects (continued)
SolutionClosed defect summary
Fixed in Fabric OS 7.1.0.End to End (EE) monitor may behave unexpectedly when
configured on ports with no traffic.
Workaround prior to upgrade:The Encryption Engine does not send the
"Load,Unload;Load" SCSI command to the Virtual Initiator.
A host port toggle could be used to recover.
Fixed in Fabric OS 7.1.0.
Fixed in Fabric OS 7.1.0.The spinfab reports a failure on switches running Fabric
OS 6.4.x to switches with Fabric OS 6.2.x.
Workaround prior to upgrade:A fabric with ETIZoning, data stops flowing when switching
zoning enforcement from "Hard-Port" <--> "Hard-Wwn".
Users can toggle the port (disable/enable) to correct the
issue.
Fixed in Fabric OS 7.1.0.
Fixed in Fabric OS 7.1.0.An F-Port trunk loses connectivity after an HA Failover.
Workaround prior to upgrade:A disk Controller warm start processing causes multiple
IFCCs.
Disable emulation.
Fixed in Fabric OS 7.1.0.
Fixed in Fabric OS 7.1.0.While running diagnostics, an unsuccessful read at a low
level or bad SFP/media can trigger a switch panic.
Fixed in Fabric OS 7.1.0.In Web Tools, appropriate validation checking is missing,
which can lead to configuration missteps.
Fixed in Fabric OS 7.1.0.Fabric Watch messages report TX/RX values above 100%.
Fixed in Fabric OS 7.1.0.portloopbacktest options are not working properly
on 16 Gb/s blades.
Fixed in Fabric OS 7.1.0.After an HA Reboot on a Brocade 5460 switch, internal
ports go offline/online with warm recovery.
Workaround prior to upgrade:SRDF replication cannot handle busy response to
commands with FCIP FastWrite enabled.
Disable emulation.
Fixed in Fabric OS 7.1.0.
Fixed in Fabric OS 7.1.0.When a fabric rebuild and merge event occur close
together, the domain goes out of sync and the new device
will have the incorrect PID and be inaccessible to others.
Fixed in Fabric OS 7.1.0.After running sshutil delpubkeys, the admin account
is locked out. Users must login as root and delete the known
hosts file to correct the issue.
Fixed in Fabric OS 7.1.0.Unable to add more than one FCIP circuit, even when an
AE license is installed after configdefault.
Fixed in Fabric OS 7.1.0.Switches running Fabric OS 7.x may experience I/O
disruption. In a multiple trunk group scenario to the same
domain, a trunked link may be abandoned when the
bandwidth is not the same as the other trunked link causing
the I/O disruption.
Fixed in Fabric OS 7.1.0.The SKM log periodically displays the error message
"Unknown key name or insufficient permissions”.
Fixed in Fabric OS 7.1.0.A CP panic and unintended HA Failover may occur when
reseating core blades.
52